Draft 02 - Sep 1 2015
9-8
Viking Mobile Radio Operating Manual
Tones & Error Messages
9.3
Viking LED Failure Codes
SECURE_ONLY
“Secure Only”
“SECR ONLY”
“Secure Only”
The user is attempting to transmit Clear on a Strapped Secure
channel.
SLAVE_SCAN
“Slave Scan”
“SLAVE SCAN”
“Slave Scan”
If a conventional scan list is slaved to the current zone, this
error will occur if the user attempts to select or edit another
conventional scan list.
STATUS_FAILED
“Status Fail”
“STS FAILED”
“Status Fail”
This error indicates that no acknowledgement was received
while sending a status report.
TEMP_HOT
“Hot”
“HOT”
“Hot”
This error indicates that the mobile has passed the hot
temperature threshold. If the user transmits in this condition,
the radio will display “Hot” and “Low Power”. Transmit power
will be forced low.
TEMP_TOO_HOT
“Too Hot”
“TOO HOT”
“Too Hot”
This error indicates that the mobile has passed the TOO HOT
temperature threshold. Under these conditions the radio will
not allow transmit.
TX_TIMEOUT
“Tx Timeout”
“TX TIMEOUT”
“Tx Timeout”
This error indicates that the transmit timeout timer has expired
and transmit has been terminated.
VOLTAGE_HIGH
N/A
“VOLT HIGH”
“Voltage High”
The mobile’s voltage source is too high. Transmit is not
allowed in this condition.
VOLTAGE_LOW
N/A
“VOLT LOW”
“Voltage Low”
The mobile’s voltage source is too low. Transmit is not
allowed in the condition.
ZONE_FAIL
“Zone Fail”
“ZONE FAIL”
“Zone Fail”
If Site Trunking and Display Site Trunking are enabled, this
will be displayed if the zone controller goes down.
Message Enumerations
Portable/SCH/LCH
Strings
Description
Orange LED Blinks
Startup Failure
Description
2
Bad File Format
The parameter file has a newer file format version than what
matches the software in the radio.
3
Parms Fail
There is no parameter file in the radio.
4
Bad Band
The radio band in the parameter file does not match the radio
band in the tuning parameters. You will see this message if a
parameter file for the wrong band is downloaded to the radio.