background image

TT-107IU Silicone Keyboard       -      Technical Documentation 

15.05.2012                    © E.L.B. Ex-Geraete Bachmann GmbH                                      Page  3

General Information 

 

In short 

Advantages of the keyboard TT-107IU: 

  Suitable for hazardous areas zone 1, 2 (gas), 21 and 22 (dust) 

  Integrated mouse pad with special functions 

  USB device; one cable only for keyboard and mouse 

  Well palpable keys, easy to find even with gloves 

  Switch point easy to feel 

  Case without gaps and edges, easy to clean 

  Case, lead and plug (silicone) resistant against most chemical fluids 

  Dust and water proof, e.g. IP 68 (immersion) 

  Suitable intrinsically safe interface and supply available (W...-Q) 

 
 
 
 

Delivery components 

Delivery includes: 

-

 

Keyboard TT-107IU (available in black only) 

-

 

Manual 

 
 
 

Handling hints 

 
Installation 

Keyboard  and  mouse  pad  install  themselves  automatically  on  your  PC  as 
“HIDs”  (human  interface  devices).  There  is  no  driver  CD  necessary.  Further-
more the USB plug may be connected before or after starting the PC. 

With every powering-up the keyboard first checks the maximum possible data 
rate  of  the  USB  channel.  If  the  data  rate  is  less  than  480  Mbit/s  (USB  2.0, 
“high  speed“)  a  message  appears  on  the  screen  like  this:  “This  device  might 
work  better  with  a  high-speed  USB  connector”,  and  the  keyboard  switches 
back to 12 Mbit/s (USB 1.1 “full speed“). Actually this does not slow down the 
data  rate,  because  “full  speed”  is  sufficient  by  far.  Frequency  testing  and 
message are just parts of standard routines, which can also be found in slow 
USB devices. 

The  reason  for  this  message  may  be  a  long  cable  or  an  intrinsically  safe 
supply connected with the keyboard. In both cases capacitances between the 
cable  leads  or  of  protective  diodes  disturb  the  transmission  of  high 
frequencies.  However,  when  the  message  “Device  not  recognized”  appears, 
even USB 1.1 “full speed” cannot be achieved or there is another failure. 
 

Summary of Contents for TT-107IU

Page 1: ...B EX GERAETE 15 05 2012 TT 107IU Technical Documentation ...

Page 2: ...mponents 3 3 Handling Hints 3 4 Marking for Hazardous areas 6 5 Intrinsic Safe Supply and Data Transmission 7 Order examples 7 8 6 General Data 6 1 Current Consumption 8 6 2 Weights and measures 8 6 3 IP Degree 8 6 4 Extension Cables 9 6 5 Connectors in Hazardous Areas 9 Appendix 7 Safety Advices 10 8 Liability 11 9 Declaration of Conformity 11 10 Certificate 12 ...

Page 3: ...an interface devices There is no driver CD necessary Further more the USB plug may be connected before or after starting the PC With every powering up the keyboard first checks the maximum possible data rate of the USB channel If the data rate is less than 480 Mbit s USB 2 0 high speed a message appears on the screen like this This device might work better with a high speed USB connector and the k...

Page 4: ...g of one finger over the pad moves the mouse pointer over the screen Please read about additional functions which you might initiate by mistake 1 Tapping on the pad in general No powerful knocking necessary Just lay down your finger s gently on the pad surface without hurry while double clicking 2 Tapping on the pad with one finger a Tapping once Tapping once on the pad with one finger works like ...

Page 5: ...wheel When the black double arrow converts into a single pointer the screen starts to move over the document in the pointed direction The scroll velocity corresponds to the distance between the arrowheads and the pointer Scrolling continues with no finger on the pad Putting a finger on the pad and sliding again may change the scroll velocity and direction Two fingers on the pad pressing the mouse ...

Page 6: ... 107IU must be supplied by an ATEX certified intrinsically safe supply which fits to the electrical data listed above This is valid for the dust atmosphere models too We recommend the USB supply series W Q which is meant for operating inside of gas hazardous areas In dust atmosphere however USB sockets are not allowed because the contacts are not dust protected Danger of ignition of conductive dus...

Page 7: ...st protected Danger of ignition of conductive dust But the keyboard itself may be operated in dust areas Please find more connection possibilities in the USB sticks data sheets 3 Order examples TT 107IU Intrinsically safe USB keyboard with mouse pad and ca 2 1 m cable WR Q 005 A Intrinsically safe supply with 50 cm cable flying leads and attached USB plug UClamp1 Connector for WR Q 005 A with clam...

Page 8: ...d directly with the PC without intrinsically safe supply 2 With intrinsically safe supply between PC and keyboard 3 After some period without operation 6 2 Weights and measures Dimensions 340 x 165 x 21 5 mm Weight ca 1200 g Cable length ca 2 1 m Under the bottom plate there are four nuts size M5 for fastening the key board to a desktop They are covered by stoppers or plastic screws The easiest wa...

Page 9: ...be found in the certificates of the terminal blocks or the junction boxes The maximum cable length is not predictable because many USB devices refuse to install themselves if the USB cable does not transmit frequencies which are much higher than the actual data transmission rate If you need especially long cables please give us a message The lead colours of USB cables are standardized see drawing ...

Page 10: ...e unit and secure it against being used again Installation maintenance and cleaning of the units must only be performed by persons trained and authorized for this purpose insofar as they are familiar with the units It is prohibited for the operator or his staff to open the units in a way that is not described in this manual This may only be done by specifically authorized personnel of E L B Ex Ger...

Page 11: ...ation must be observed Model Silicone USB keyboard with mouse pad TT 107IU Directive EMC Directive 2004 108 EG European Standards EN 55022 2008 07 EN 55024 2003 10 Directive Low Voltage Directive 2006 95 EC European Standards EN 60950 2011 01 Directive 94 9 EC European Standards EN 60079 0 2009 EN 60079 11 2007 EN 61241 11 2006 EN 61241 0 is part of EN 60079 0 The certificate printed on the follow...

Page 12: ...TT 107IU Silicone Keyboard Technical Documentation 15 05 2012 E L B Ex Geraete Bachmann GmbH Page 12 10 certificates ...

Page 13: ...TT 107IU Silicone Keyboard Technical Documentation 15 05 2012 E L B Ex Geraete Bachmann GmbH Page 13 ...

Page 14: ...TT 107IU Silicone Keyboard Technical Documentation 15 05 2012 E L B Ex Geraete Bachmann GmbH Page 14 ...