9
‐
2.5 RS485
When the DVR receives a camera control command, it transmits that
command up the coaxial cable to the PTZ device. RS485 is a single-direction
protocol; the PTZ device can’t return any data to the unit. To enable
X289
H289H289H X
Since RS485 is disabled by default for each camera, you must
enable the PTZ settings first. This series DVRs support multiple protocols such
as Pelco-D, Pelco-P. To connect PTZ devices to the DVR:
1. Connect RS485 A,B on the DVR rear panel.
2. Connect the other end of the cable to the proper pins in the connector on the
camera.
3. Please follow the instructions to configure a camera to enable each PTZ
device on the DVR.
3. Boot up and Shutdown
3.1.1 Boot up and Shutdown
Boot up
Before the boot up, please make sure:
The rated input voltage matches the device power on-off button. Please
make sure the power Wire connection is OK. Then click the power on-off
button.
Always use the stable current, if necessary UPS is a best alternative
measure. Please follow the steps listed below to boot up the device
Connect the device to the monitor and then connect a mouse.
Connect power cable
Click the power button at the front or rear panel and then boot up the
device. After device booted up, the system is in multiple-channel display
mode by default.
Shutdown
Note
When you see corresponding dialogue box “System is shutting down…” Do not
click power on –off button directly.
Do not unplug the power cable or click power on-off button to shutdown
device directly when Device is running (especially when it is recording.)
There are three ways for you to log out.
a)Main menu (
RECOMMENDED
)
From Main Menu->Shutdown, select shutdown from dropdown list.