H700 User Manual
E-Lins Technology Co.,Limited
Tel: +86-755-29230581 E-mail: sales@e-lins.com www.e-lins.com
DIO trap
: send SNMP trap when DIO changed from 1 to 0, or 0 to 1.
Set DIo to high for a period of time
: If set DIO to high after a period of time, DIO will
goto low automatically, value 0 means disable.
DIO_0 default value
: DIO default value is low(0). if set to high(1), when device is up, it
will be set to high automatically.
DIO_1 default value
: DIO default value is low(0). if set to high(1), when device is up, it
will be set to high automatically.
DIO_2 default value
: DIO default value is low(0). if set to high(1), when device is up, it
will be set to high automatically.
DIO_3 default value
: DIO default value is low(0). if set to high(1), when device is up, it
will be set to high automatically.