Troubleshooting 

Troubleshooting 

 

 

 

Verify that you are using a power supply ranging from 12 to 48VDC.    Applying 

more than 48VDC could cause damage to the switch. 

 

Be sure the proper cable is used in your network.    Refer to the Cabling section of 

this manual for help. 

 

Diagnosing LED Indicators: The switch can be monitored through the LED 

indicators on the front panel of the switch.    The LED’s can help describes common 

problems you may encounter and where you may find possible solutions, to assist in 

identifying problems. 

 

If the power indicators do not light on when power is applied, you may have a 

problem with the power supply. Check for loose power connections, power losses or 

surges at the power outlet.   

 

If the switch LED’s represent normal operating mode and the cable connections are 

correct and no data is transmitted or received through the switch, contact your 

Network Administrator for network configuration and status help. 

 

18

  

      Manual Documentation Number EIR410-2SFP-T – 0109m 

www.bb-elec.com

 

www.bb-europe.com

 

Summary of Contents for EIR410-2SFP-T

Page 1: ...Manual Documentation Number EIR410 2SFP T 0109m www bb elec com www bb europe com E EI IR R4 41 10 0 2 2S SF FP P T T U Us se er r M Ma an nu ua al l...

Page 2: ...353 91 792445 Website www bb europe com 2008 B B Electronics Mfg Co Inc No part of this publication may be reproduced or transmitted in any form or by any means electronic or mechanical including phot...

Page 3: ...s 6 Cabling 10 Wiring the Power Inputs 11 Wiring the Fault Alarm Contact 12 3 Mounting Installation 13 DIN Rail Mounting 13 Wall or Panel Mount Plate Mounting 15 4 Hardware Installation 16 Installatio...

Page 4: ...Mode o Store and Forward Switching Architecture o Back plane Switching Fabric 5 6Gbps o 1Mbits Packet Buffer o 8K MAC Address Table o Supports Wide Operating Temperature of 40 to 75o C Power Supply o...

Page 5: ...Documentation Number EIR405 T 0109m www bb elec com www bb europe com Package List 1 EIR410 2SFP T 10 Port Gigabit Industrial Ethernet Switch 1 Quick Start Guide 1 CD ROM with User Manual 2 Wall Mount...

Page 6: ...cription Physical Dimension W x D x H is 72mm x 105mm x 152mm 2 8 x 4 1 x 6 0 inches Front Panel The Front Panel of the EIR410 2SFP T is shown below 3 Manual Documentation Number EIR410 2SFP T 0109m w...

Page 7: ...entation Number EIR405 T 0109m www bb elec com www bb europe com Top View The top panel view of the EIR410 2SFP T is equipped with one terminal block connector that consists of two 12 to 48 VDC power...

Page 8: ...e Fault Off Power 1 and 2 are both functional or no power is applied Green Connected to network Blinks Networking is active P9 P10 10 100 1000T Upper LED Off Not connected to network Green The port is...

Page 9: ...orts auto sense for 10 100 or 1000 Mbps device connections The auto MDI MDIX feature allows connections to switches workstation and other equipment without changing straight through or crossover cabli...

Page 10: ...it Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD Straight Through Cable Schematic Cross Over Cable Schematic 2 Gigabit Copper SFP mini GBIC combo ports The EIR410 2S...

Page 11: ...at the same time The SFP module has the highest priority If a 1000M SFP transceiver is inserted into the SFP cage and a remote device is connected to the SFP port the copper combo port will link down...

Page 12: ...5 T 0109m www bb elec com www bb europe com Make sure the module is aligned correctly and then slide the module into the SFP slot until a click is heard Transceiver Inserted Second insert the fiber ca...

Page 13: ...down and pull it out before releasing Remove LC connector Second swivel the metal latch away from the switch and pull the transceiver out Pull out from the transceiver Cabling Use unshielded twisted p...

Page 14: ...b elec com www bb europe com Wiring the Power Inputs Follow the steps below to insert the power wire 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector...

Page 15: ...The fault alarm contact is in the middle of the terminal block connector as shown below If one of the power sources fails a fault will be detected causing the circuit to open www bb europe com Insert...

Page 16: ...p is not screwed on the switch please see the following figure to re attach the DIN Rail clip Then follow the steps below to hang the switch onto a DIN rail 1 Use the screws to screw the DIN rail clip...

Page 17: ...e rest of the way onto the DIN rail track 5 Check that the switch is held tightly to the DIN rail track 6 To remove the switch from the track reverse the steps above First pushing down lightly on the...

Page 18: ...1 Remove the DIN rail clip from the switch loosen the screws to remove the DIN rail clip 2 Place the wall mount plate on the rear panel of the switch 3 Use the screws to screw the wall mount plate ont...

Page 19: ...ower Inputs section for knowing the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights...

Page 20: ...Network Application Network Application The diagram below shows a typical switch installation for the EIR410 2SFP T 17 Manual Documentation Number EIR410 2SFP T 0109m www bb elec com www bb europe com...

Page 21: ...ommon problems you may encounter and where you may find possible solutions to assist in identifying problems If the power indicators do not light on when power is applied you may have a problem with t...

Page 22: ...r Gigabit Fiber Ethernet port Memory Buffer 1Mbits MAC address 8K MAC address table LED 8 ports 10 100TX Link Activity Green Full duplex Collision Yellow Giga port Link Activity Green Per unit Power 1...

Page 23: ...ps at 64bytes Power Supply 12 to 48 VDC Redundant power with reverse polarity protection and removable terminal block Power consumption 6 76 Watts Install DIN rail or panel wall mount Operation Temp 4...

Page 24: ...l Specification 21 Manual Documentation Number EIR405 T 0109m www bb elec com www bb europe com Safety UL cUL CE EN60950 1 Stability testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vi...