INSTALLATION
The unit has a sensing angle of 360°. It detects micro movement within a 3.5m
RADIUS (sitting zone) and can detect general movement up to 5M RADIUS at a
mounting height of 2.5 meters. (FIGURE 2)
.
FIGURE 2
SCHEMATIC
FIGURE 3
WIRING INSTRUCTION
(1) Switch off the power source or wall switch.
(2) Strip approximately 6-8mm insulating part of the wires from the power cord.
(3) Connect the BROWN wire (Live wire) of power cord to the terminal block "L"
mark.
Connect the BLUE wire (Neutral wire) of power cord to the terminal block “N”
mark.
Connect the BROWN wire of lamp wire to the terminal block "LS" mark.
(FIGURE 4)
FIGURE 4
(4) Fit the main body to the wall box of the ceiling and secure it with two fixing
screws provided. (FIGURE 5)
FIGURE
5
The product is also designed to fit a standard UK spec pattress box.
SETTING THE LIGHTING SYSTEM
(1) TEST
MODE
Turn the Lux control and the Time control counter-clockwise to the edge-the
TEST position. (FIGURE 6)
L
N
AC POWER
Brown
Blue
Red