The servo amplifier SCA-LS-30-03 is a powerful servo 
amplifier for brushed DC motors with an output range up 
to 75 Watt. 
These operation modes are integrated 

• 

Current control 

• 

I x R control 

• 

DC-Tacho control 

• 

Voltage control 

• 

Optional: encoder feedback 

 
The required operation mode is to be selected with 
jumpers, which are accessible externally at any time. This 
SCA-LS-30-03 servo amplifier is protected against over 
current and overheat. Due to the linear final stage an 
additonal inductance is not necessary. Due to the wide 
range of power supply voltage between 11 to 30 V DC the 
SCA-LS-30-03 can be used very flexible with different 
kinds of power supplies. The robust aluminium case has 
been constructed for different methods of mounting it, therefore a fast and easy integration is provided. 
Screw terminals and a durable controller-design allow a fast and straightforward commissioning. 
 
 
 

Contents 

 

1.

 

Safety notes.............................................................................................................................................1

 

2.

 

Specification............................................................................................................................................2

 

3.

 

Description of inputs and outputs........................................................................................................3

 

4.

 

Configuration ..........................................................................................................................................5

 

5.

 

Operating modes....................................................................................................................................6

 

6.

 

Connection of inputs and outputs........................................................................................................7

 

7.

 

Commissioning .......................................................................................................................................8

 

8.

 

Troubleshooting .....................................................................................................................................9

 

9.

 

Dimensions..............................................................................................................................................9

 

10.

 

Versions of Text......................................................................................................................................9

 

 

1.  Safety notes 

1.1.  Skilled personnel 

The installation and commissioning have to be done only by skilled personnel. 

 

1.2.  Laws 

The user has to ensure the correct installation of the servo amplifier and additional equipment 
according to valid laws and rules. 

 

1.3.  Remove load 

For first commissioning the motor should run with free shaft which means without load. 

 

1.4.  Additional safety components 

Electronic components are not free of failure or damage. Therefore plants have to be installed with 
additional device and installation protecting components. A safe and stable state has to be ensured in 
the case of damage of some devices, wrong handling, cable disruption and other cases of any kind of 
malfunction. 

Summary of Contents for SCA-LS-30-03

Page 1: ...ed for different methods of mounting it therefore a fast and easy integration is provided Screw terminals and a durable controller design allow a fast and straightforward commissioning Contents 1 Safe...

Page 2: ...9 336 EWG article 10 and appendix 1 EMV amended by 92 31 EWG and 93 68 EWG and meet the requirements with standard EN 61800 3 1996 if the following directions are observed usage of a zinc plated mount...

Page 3: ...ected to an differential amplifier Input voltage range 10 V 10 V Input impedance 100 kOhm Definition of polarity positive set value Set value Set value negative set value Set value Set value Input con...

Page 4: ...o 1k 33k 100k 33k 50k 100k 4k7 GNDA 3 1 5 Vcc 3 3 1 6 Power GND 4 Power supply connector Caution DO NOT connect Vcc and Power GND to the outputs Motor or Motor 3 2 Outputs 3 2 1 Auxiliary voltage outp...

Page 5: ...is no direct connection to Power GND or GND Signal These auxiliary voltage outputs are for connection with an external potentiometer and must not be connected to any other pin or for any other purpos...

Page 6: ...D 70567 Stuttgart Germany Tel 49 0 711 7221535 Fax 49 0 711 7221548 E mail mgmt e motion controls com 4 2 Selection of Input for Set Value Jumper 5 6 Via Offset Pot J5 J6 Via Ext Pot J5 Via Set Value...

Page 7: ...l free switch no Enable V 14 13 Enable In 6 2 Input for Set Value The set value for speed Operating modes I x R Voltage Control Tacho respectively motor current Operating mode Control can be set on th...

Page 8: ...4 Adjustment 1 Adjust max set value e g 10 V and turn potentiometer n max cw til the required speed is reached 2 Adjust potentiometer Imax to required value of current limitation Important Refer to mo...

Page 9: ...ted too low Check potentiometer adjustment I max Speed range too low Check potentiometer adjustment n max Wrong operation mode Check jumper setting Bad connections Check connectors Motor does not turn...