1.5. Repairs
Repairs have to be done only by authorized distributors or at the manufacturer. Unauthorized opening
and improper repairs of the device may cause danger to the user and the plant.
1.6. Danger
Care about having no power supply voltage all around the plant during installation of the device!
Never touch any voltage-carrying components!
1.7. Maximum input voltage
The input power supply voltage must not exceed 30 V DC. Voltages exceeding 30 V or reversed
connection will destroy the unit.
1.8. ESD
Do not touch any of the contacts of the device.
1.9. EMC
The SCA-LS-30-03 corresponds to the EC directives,standards and regulations 89/336/EWG article
10 and appendix 1 (EMV) amended by 92/31/EWG and 93/68/EWG and meet the requirements with
standard EN 61800-3 (1996) if the following directions are observed:
•
usage of a zinc plated mounting plate, well connected to earth
•
mounting of the drive by usage of toothed washers
•
usage of shielded cables to and from the unit
•
large area contact of the shielding with zinc plated mounting plate.
•
motor housing properly connected to earth
Special requirements have to be considered by the user.
2. Specification
Power supply voltage
11 - 30 V DC
2.1. Electrical
data
Nominal output current
3 A
Set value
- 10 ... + 10 V
Tacho
Max 50 VDC (50kOhm)
2.2. Inputs
Enable
8 - 30 V high active
Supervision output Error
Open Collector max. 30 V DC
2.3. Outputs
Auxiliary voltage /- reference
+/- 3,9 V/max. 20mA
2.4. Display
2-colour LED
green: ready/enabled, red: error/disabled
2.5. Weight
With terminal connector
330 g
2.6. Dimensions
(DxWxH)
100 x 117 x 40 mm
Operation
0 ... + 40
o
C
2.7. Temperature-
range
Storage
- 30 ... + 80
o
C
2.8. Humidity
range
Non condensing
20% - 80% rel. hum.