26
5 Mounting
Please ensure sufficient space for the mating plugs of the load terminals and the supply.
The device must be fixed with four M4 screws before connecting the cables (see dimensional drawings). Mounting screws are not
included in the scope of delivery.
Ensure that the device is installed in an area where the ambient temperature does not exceed 85 °C or that there is sufficient air flow.
Please provide additional protection against overload in the supply line (b) according to the max. current. In the
event of overload, the machine may be damaged.
SCS3000 and SCS1000 harnesses designed for current rating including mating connectors are not included in the scope
of delivery, but can be obtained from E-T-A.
6 Tests and technical data
6.1 Environmental tests and approvals
The following approval test was carried out for all SCS1000 versions:
The following approval test was carried out for all SCS3000 versions:
The following tests were carried out for all SCS1000 and SCS3000 versions:
Name
Chapter / section
Comments
E11
Directive R-10, regulatory status 5
VCA, approval mark E11*10R05/00*11361*00
Name
Chapter / section
Comments
E11
Directive R-10, regulatory status 5
VCA, approval mark E11*10R05/00*11360*00
Name
Chapter / section
Description
ISO 16750-2
4.4
Superimposed alternating voltage
ISO 16750-2
4.6.1
Momentary drop in supply voltage
ISO 16750-2
4.6.2
Reset behavior
ISO 16750-2
4.6.3
Starting profile
ISO 16750-2
4.6.4
Load dump
ISO 16750-2
4.7.2
Reversed voltage
ISO 16750-2
4.8.2
Ground reference and supply offset
ISO 16750-2
4.10.1 / 4.10.2.1
Short circuit protection
ISO 16750-3
4.1.2.4
Passenger vibration @ temperature
ISO 16750-3
4.1.2.7
Commercial vibration @ temperature