59
• Mil CAN
For internal use only. Do not use this option.
• Serial baud rate
Changing the baud rate of the serial interface. The baud rate must be the same for all devices at the bus.
• CAN baud rate
Changing the baud rate of the CAN bus. The baud rate must be the same for all devices at the bus.
• Datastream TX rate
Transmission rate of the datastream in Hz (applies to datastream V1).
• 29bit CAN IDs
Allows the use of 29-bit identifiers
• CAN termination
For internal use only. Do not use this option.
The SCS1000 and SCS3000 modules have no integral CAN termination.
• 0.2 A CAN resolution
Switch between 0.5 A measured value resolution and 0.2 A measured value resolution (current values)
• 0.02 V ANxV CAN resolution
Switch between 0.2 V measured value resolution and 0.02 V measured value resolution of the analogue inputs
If 0.02 V measurement resolution is selected, only voltage values up to 5 V can be displayed.
• Soft I/P base (preV2.9)
Start address of the soft I/Os (only for PDU firmware before V2.9)
• Datastream base ID
Start address of the CAN datastream containing output states and load current values of the PDU
• Datastream version
Selection of the datastream data format (see also 7.3)
• Fault reset ID
The reception of a CAN frame with the set ID and any data content is used to acknowledge an error message. Resetting an error
can also be done by using the RESET schematic diagram symbol.
• Grayhill switch panels
To integrate Grayhill keypads, select this option together with the »Switch Panel 1/2« option
• Switch panel 1/2
To integrate keypads, select these options - some soft I/Os are reserved for keypad communication
• Datastream frame frequencies
Determine the individual transmission rate of each frame of the datastream. Applies to datastream V2 and V3, transmission
frequency can be set between 1 Hz and 100 Hz.
• Soft I/O frame IDs and frequencies
Manual setting of the soft I/O addresses (8 bits per I/O) and the transmission rates of the soft outputs.