43
After a free fall, all relays and fuses of the SCS200-RC... version must be pushed in again into the socket. The impact may
have loosened the tight fit of the components.
High vibration values may lead to a deterioration of the internal resistance values in the sockets over the entire life span.
This can be remedied by removing and re-inserting the components.
The following chemical loads were tested:
• Diesel AA
• Motor oil BA
• Hydraulic fluid BD
• Battery acid CA
• Urea CD
• Vehicle cleaner DB
• Acetone DG
• Cleaning agent containing ammonium DJ
• Spirit DK
• Transpiration
• Cosmetic products EC
• Soft drinks containing caffeine and sugar ED
• Cream, coffee whitener EF
Exposure to battery acid may cause external damage to the housing (illegible product marking), but this will not affect the
functionality of the SCS200.
However, it is recommended to replace the device in this case.
To prevent damage, after exposure to chemical loads, these must be immediately removed from the device.
Name
Chapter/section
Comments
ISO 16750-4
5.1.2.2
Operation at +90 °C
ISO 16750-4
5.2
Temperature step test
ISO 16750-4
5.3.1
Temperature cycle test
ISO 16750-4
5.3.2
Rapid change of temperature
ISO 16750-4
5.6.2.2
Damp heat cyclic test
ISO 16750-4
5.7
Damp heat, steady-state test
ISO 16750-4
5.10
Dust test (covered by IP testing)
ISO 16750-5
4
Chemical loads