10
Basic operating
features
“BT” Button triggers.
Condominium auto-close mode.
The BT functions are the primary full gate opening functions for motor vehicle access.
There are two ways of activating the “BT” functions on this control card. Either via the hardwired BT input or the BT receiver channel.
In Condominium auto-close mode, all BT triggers are treated as open, keep opening, keep open or re-open triggers. The gates will only close once the
BT auto-close timer has timed out.
In Condominium auto-close mode the following advanced features are NOT available: - Holiday lock-out and Party mode.
NB!
For any auto-close feature to work, a pair of safety infra-red beams must be installed and functioning correctly. If no safety infra-red beams are
installed then the gates will open but not close again.
Action
Response
Momentary BT trigger.
Gate begins
opening.
No buzzer tones.
Momentary BT trigger
while gate is opening.
The trigger is
ignored and the
gate continues
opening.
No buzzer tone.
At full open position.
Gate stops
and auto-close
timer starts
counting down.
No buzzer tones.
Momentary BT trigger.
Gate remains
open and auto-
close timer
resets.
No buzzer tones.
Auto-close timer
timeout. Safety beam
input not triggered.
Gate begins
closing.
No buzzer tones.
Momentary BT trigger.
Gate stops and
immediately
starts opening
again.
No buzzer tones.
At full open position.
Gate stops
and auto-close
timer starts
counting down.
No buzzer tones.
Auto-close timer
timeout. Safety beam
input not triggered.
Gate begins
closing.
No buzzer tones.
At full closed position.
Gate stops.
No buzzer tones.
0
0 sec.
c.
0
0 sec.
c.
0
20 sec.
0
20 sec.
0
20 sec.
Gate closed.