13
“PED” Pedestrian trigger.
(With safety beams installed)
Basic operating
features
The PED trigger is a higher security option and is used when access to or from the property is limited to exclude motor vehicles.
If the safety beams are triggered while the gate is closing in pedestrian mode, the gate will only return to the preprogrammed pedestrian open
position.
If the Loop or the BT triggers are activated at any time during the pedestrian routine, the gate will open to the full open position and the pedestrian
transaction is cancelled. The system then reverts to either the Loop or BT trigger mode depending on which was triggered.
There are two ways of activating the “PED” functions on this control card. Either via the hardwired PED input or the PED receiver channel.
Action
Response
Momentary PED trigger.
Buzzer beeps
pre-run
warning.
After buzzer silences.
Gate begins
opening.
No buzzer tones.
At previously
programmed
pedestrian opening
distance.
Gate stops and
the pedestrian
auto-close
timer starts
counting down.
No buzzer tones.
Momentary PED trigger
or safety beam circuit
trigger.
Pedestrian
auto-close
timer resets.
No buzzer tones.
Pedestrian auto-close
timer times out.
Buzzer beeps
pre-run
warning.
After buzzer silences.
Gate begins
closing.
No buzzer tones.
At full closed position.
Gate stops.
No buzzer tones.
x3
STOP
5 sec.
0
STOP
5 sec.
0
STOP
0
0 sec.
c.
x3
STOP
Gate closed.