Basic operating features.
Safety infra-red beams function.
If the safety beam input has been switched on, the control card will constantly monitor to ensure a set of safety beams is installed.
NB!
If the BT input mode has been set to either simple auto-close or condominium mode, the safety beam input is forced on.
If the BT input has been set to standard mode and either the loop detector or pedestrian input is activated, the safety beam input is
forced on for that transaction only.
Below is an example of how the gates will behave whenever the safety beam input is activated.
Gates in the closed position
Action
Response
Momentary BT trigger.
Gates begin
opening.
No buzzer tones.
Safety beam input
triggered.
Gates
continue
opening.
No buzzer tones.
At full open position.
Gates stop.
No buzzer tones.
Momentary BT trigger.
Gates begin
closing.
No buzzer tones.
Safety beam input
triggered.
Gates stop
closing and
begin
opening
immediately.
No buzzer tones.
At full open position.
Safety beam input still
triggered.
Gates stop.
No buzzer tones.
Momentary BT trigger.
Safety beam input still
triggered.
Gates remain
open.
No buzzer tones.
Momentary BT trigger.
Safety beam input no
longer triggered.
Gates begin
closing.
No buzzer tones.
At full closed position.
Gates stop.
No buzzer tones.