7
INSTALLATION
DOMESTIC HOT WATER CONNECTION
Pressure reducer
If the water mains pressure is greater than 6 bar, a pressure reducer
calibrated to 4.5 bar must be fitted.
Safety unit
The tank safety unit must be ACV approved and calibrated to 7 bar.
The valve discharge must be connected to the waste water disposal
system.
Domestic hot water expassion tank
Installing a domestic hot water expansion tank avoids any risk of
overpressure due to pressure surges and also makes sure that
there is a always water flowing through the safety unit when refilling
the domestic hot water tank.
Hot water circulation
If the tank is located a long way from the point of use, then
installing a closed recirculation circuit ensures that a faster supply
of hot water is always available.
Descriptions
1.
Expansion relief valve
2.
Pressure reducing valve
3.
Thermostatic mixing valve
4.
Hot water secondary pump (it fitted)
5.
Non-return valve
6.
Hot water expansion vessel
7.
Stop cock
8.
Draw-off valve
9.
Drain cock
CONTROLLER KITS
KIT 1: ACV 13.00 / Basic
Basic kit for regulating initial flow temperature according to weather
conditions. It comprises: a temperature regulator with analogue
clock, wall-mounted water temperature sensor (-30/130 °C), external
sensor (-30/50 °C), 3-pin servomotor SQY 31 230 V and an
intermediate base.
KIT 2: ACV 13.00 / Standard
Basic kit for regulating initial flow temperature according to weather
conditions. It comprises: a temperature regulator with analogue
clock, wall-mounted water temperature sensor (-30/130 °C), external
sensor (-30/50 °C), 3-pin servomotor SQY 349,230 V and an
intermediate base.
1
2
4
6
5
7
9
8
3
IMPORTANT
As a safety measure against burns, we strongly advise
installing a thermostatic mixing valve (recommended
temperature: 60° C).
Optional fittings available
Groupe de sécurité
Ø 3/4”
Réducteur de pression
Ø 3/4“
Mitigeur thermostatique
Ø 3/4”
Vase d’expansion
5 litres