16. ELECTRICAL EQUIPMENT E-TON
16-6
Battery
Removal
Remove the 4 screws on the battery cover.
(Screws x 4).
CAUTION
Remove the battery cover.
Disconnect the negative (-) cable from the
battery first, then the positive (+) cable.
Remove the battery.
Install the battery in reverse order of
removal.
CAUTION
z
Electrolyte (diluted sulfuric acid) is very
toxic. Once it spreading on clothes,
skin, or eyes, it will cause burned or
blind. In case of being spread, flush
with great quantity of water immediately,
and then send to hospital.
z
When clothes is spread by electrolyte, it
will contact with skin. So, it must flush
with great quantity water to take off the
clothes.
z
To prevent form circuit short, connect
po) terminal at first, and next
negative (-) terminal.
positive (+)
negative (-)
C.D.I.
fuse
Battery cover
4 screw
Summary of Contents for sport 50
Page 129: ...13 BRAKE E TON 13 2 Rear Drum Brake System 0 8 1 2 kgf m 0 8 1 2 kgf m...