ELEC
7 - 29
SIGNALING SYSTEM
4.
The neutral indicator light fails to come on.
1. Neutral indicator light bulb and socket
• Check the neutral indicator light bulb and
socket for continuity.
Refer to “CHECKING THE BULBS AND
•
Are the neutral indicator light bulb and
Replace the neutral indicator
light bulb socket or both.
YES
NO
BULB SOCKETS
socket OK?
YES
NO
2. Neutral switch
•
Check the neutral switch for continuity.
Refer to
“
CHECKING THE SWITCHES
”.
•
Is the neutral switch OK?
Replace the neutral switch.
YES
NO
3. Voltage
• Connect the pocket tester (
DC 20 V
) to the
neutral indicator light connectors (wire har-
ness side) as shown.
Positive tester probe → orange
1
Negative tester probe → green
2
• Set the main switch to “ON”.
• Set the shift rod to “N”.
• Measure the voltage (DC 12V).
• Is the voltage within specification?
G
Or
1
2
DC 20 V
3. Wiring
Check the entire signaling system’s wiring.
2. Fuel level gauge
• Set the main switch to “ON”.
• Move the float up or down.
• Check that the display segments of the fuel
level gauge increase or decrease to “E” or
“F”.
TIP:
Before reading the fuel level gauge, leave
the float in one position (either up or down)
for at least three minutes.
• Does the fuel level gauge needle move
appropriately?
Replace the fuel
level gauge.
YES
NO
(F)
(E)
This circuit is OK
The wiring circuit from
the main switch to the
neutral indicator light
connectors is faulty
and must be repaired.