background image

 

 

 

 

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com 

www.e2s.com  DC-104_Issue_A (BExS, BExL)- Page 1 of 2 - QAF_252_Issue_5

 

UKCA Declaration of Conformity 

Manufacturer:   

 

European Safety Systems Ltd. 

 

 

 

Impress House, Mansell Road, Acton 

 

 

 

London, W3 7QH 

 

 

 

United Kingdom 

 

Equipment Type:  

 

Electronic Sounders, Types BExS110D(-R)(-SIL), BExS120D(-R), 

 

 

 

Electronic Sounders, Types BExS110E(-R), BExS120E(-R), 

 

 

 

Loudspeakers, Types BExL15D(-R), BExL25D(-R), 

 

 

 

Loudspeakers, Types BExL15E(-R), BExL25E(-R),   

 

 

 

 

 

Appello Speech Sounders, Types BExA110(-R), 

 

 

 

Sontel, Types BExTS110D(-R), 

 

 

 

Hootronic Sounder, Types BExH120D(-R), 

 

 

 

Monitored Loudspeaker, Types BExL25GD(-R)

 

 

Directive  UKSI 2016:1107 (as amended by UKSI 2019:696) – Schedule 3A, Part 1 : Product or Protective System Intended for use in Potentially Explosive Atmospheres  

(UKCA) 

 

Notified Body for UK type Examination (Module B): 

UL International (UK) Ltd 

Notified Body No.: 0843 

Unit 1-3 Horizon Kingsland Business Park, Wade Road, 

Basingstoke, Hampshire RG24 8AH UK 

UK-type Examination Certificate (Module B): 

UL21UKEX2638X 

Notified Body for Quality Assurance Notification / Conformity to EU-type 

based on 

quality assurance of the production process (Module D): 

Sira Certification Service 

Notified Body No.: 0518 

Rake Lane, Eccleston, Chester CH4 9JN, UK 

Quality Assurance Notification (Module D): 

CSAE 22UKQAN0046 

Provisions fulfilled by the equipment: 

II 2G Ex db IIB 

or 

IIC T4 Gb 

II 2G Ex db eb IIB 

or 

IIC T4 Gb 

II 2D Ex tb IIIC T100°C 

or 

T105°C 

or 

T115° Db 

IP6X Dust Protection to EN60079-0 / EN60079-31 

Standards applied: 

EN IEC 60079-0: 2018 

EN 60079-1: 2014 

EN IEC 60079-7: 2015 + A1: 2018 

EN 60079-31: 2014 

Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)  

Standards applied: 

EN 61000-6-1:2007 

EN 61000-6-2:2005 

EN 61000-6-3:2007 / A1:2011 / AC: 2012 

EN 61000-6-4:2007 / A1: 2011 

Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic 

equipment, including amendment by Directive 2015/863/EU.

 

Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) 

The product and all the components contained within it are free from substances of very high concern. 

Other Standards and Regulations 

EN 60529:1991 / A1:2000 / A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67 

 

 

Summary of Contents for 1-22-070

Page 1: ...e current levels shown above are for the 440Hz Continuous tone nominal input voltage Nominal current at nominal voltage Table 1 Electrical Ratings It is important that a suitable power supply is used...

Page 2: ...f it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Hydrogen and Acetylene up to 55 C ambient Temperature Classification for Gas Applications T1...

Page 3: ...tightened to ensure that the unit cannot move in service Fig 1a Fixing Location for Sounder Flare Fig 1b Fixing Location for Sounder Radial 7 Access to the Flameproof Enclosure To access the Ex d cha...

Page 4: ...both located on the terminal chamber section of the unit Fig 3 Internal View of Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming ear...

Page 5: ...he left hand marked ve and centre pins For ve switching connect the headers to the right hand marked ve and the centre pins Refer to Fig 7 2 3 S top 1 2 3 S2 S3 Stop ve ve Stage Headers Set for ve Swi...

Page 6: ...lectro Mechanical Buzzer Sound 2 Sound 5 Sound 5 Mechanical Bell Sound 1 Sound 2 13 1 Volume Control The output level of the BEx sounder can be set by adjusting the volume control potentiometer see Fi...

Page 7: ...LINE MONITORING RESISTOR CUSTOMER SUPPLIED 500 MIN 2W MIN OR 3K3 MIN 0 5W MIN MINIMUM VALUES R1 Single Stage Configuration Config 1a Line Monitoring Header pins set to negative switching default Stage...

Page 8: ...HT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 035 R...

Page 9: ...nds B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIB or IIC T4 Gb II 2G Ex db eb IIB or I...

Page 10: ...are in accordance with the restriction of the use of hazardous substances in electrical and electronic equipment including amendment by Directive 2015 863 EU Regulation EC 1907 2006 Registration Evalu...

Page 11: ...duction process Module D Sira Certification Service Notified Body No 0518 Rake Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the eq...

Page 12: ...and Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Reviews: