E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH    sales@e2s.com        e2s.com                                            D221

-

00

-

001

-

IS Issue 1  10/05/2021 

 

 

 

 

Approved Tones for EN54

-

3 Applications:

 

 

•(

Alternating Tone) 800/1000Hz @ 2Hz Alternating Tone 44

 

•(

Rising Tone) 500/1200Hz @ 0.26Hz (3.3s on, 0.5s off) Tone 8

 

•(

Fainting Tone) 1200/500Hz @ 1Hz Tone 2

 

•(

Continuous Tone) 800Hz Tone 21

 

•(

Pulsed Tone) 660Hz (150mS on, 150mS off) Tone 31

 

•(

Alternating Tone) 544Hz(100mS)/440Hz (400mS) Tone 5

 

 

 

A112NDC024 (P2) @ 1m

 

 

Horizontal Sound Output Max Voltage (54 Vdc) LAFmax,T dB(A)

 

Horizontal Sound Output Min Voltage (11.5 Vdc) LAFmax,T dB(A)

 

Angle

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

15°

 

106.1

 

105.8

 

105.1

 

105.4

 

105.2

 

93.9

 

101.2

 

101.6

 

101.1

 

101

 

101.2

 

91

 

45°

 

105.2

 

107.2

 

106.3

 

104.1

 

98.7

 

101.6

 

101.3

 

102.9

 

102.1

 

100.2

 

94.7

 

99

 

75°

 

112.1

 

112.6

 

111.9

 

111.7

 

110.1

 

104.8

 

108.1

 

108.5

 

107.7

 

108.1

 

106.5

 

103

 

105°

 

111.9

 

112.5

 

111.7

 

111.7

 

110.2

 

104.8

 

107.9

 

108.4

 

107.6

 

108.1

 

106.4

 

103

 

135°

 

104.8

 

107.4

 

106.4

 

103.8

 

99.2

 

101.6

 

101.1

 

103.2

 

102.1

 

99.8

 

95.5

 

99

 

165°

 

105.2

 

105.8

 

105.2

 

105.3

 

105.1

 

93.8

 

100.8

 

101.5

 

100.8

 

100.9

 

102

 

90.8

 

 

Vertical Sound Output Max Voltage (54 Vdc) LAFmax,T dB(A)

 

Vertical Sound Output Min Voltage (11.5 Vdc) LAFmax,T dB(A)

 

Angle

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

15°

 

107.2

 

107.1

 

105.9

 

107.4

 

105.5

 

95.5

 

103.1

 

102.8

 

101.5

 

103.1

 

101.5

 

91.8

 

45°

 

106

 

109.3

 

107.9

 

104.6

 

100.5

 

103.7

 

102.2

 

105.4

 

103.8

 

100.4

 

96.6

 

99.9

 

75°

 

113.2

 

113.3

 

112.9

 

113

 

110.8

 

106.1

 

109.2

 

109.3

 

108.7

 

109.1

 

107.1

 

103

 

105°

 

112.9

 

113.1

 

112.7

 

112.8

 

111.4

 

106.1

 

109

 

108.9

 

108.5

 

108.9

 

107.7

 

103.1

 

135°

 

105.5

 

109.3

 

107.7

 

104.7

 

100.3

 

104.3

 

101.4

 

105.3

 

103.5

 

100.7

 

96.5

 

100.7

 

165°

 

107

 

106.5

 

105.9

 

106.4

 

105.3

 

95

 

102.6

 

102.1

 

101.5

 

102.2

 

101.1

 

91.2

 

A112XDC024 (P1) @ 1m

 

 

Horizontal Sound Output Max Voltage (54 Vdc) LAFmax,T dB(A)

 

Horizontal Sound Output Min Voltage (11.5 Vdc) LAFmax,T dB(A)

 

Angle

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

15°

 

103.3

 

103.7

 

103.1

 

103.3

 

103.2

 

91.5

 

101

 

101.5

 

100.9

 

101

 

100.3

 

89.4

 

45°

 

103.4

 

104.8

 

104.2

 

101.6

 

96.3

 

99.4

 

101.5

 

102.7

 

101.8

 

99.6

 

94.3

 

97.4

 

75°

 

109.1

 

110.4

 

109.7

 

109.6

 

108.3

 

103.2

 

107.1

 

108.2

 

107.4

 

107.7

 

105.9

 

101.4

 

105°

 

109.9

 

110.2

 

109.6

 

109.7

 

108.6

 

103

 

107.7

 

108.1

 

107.4

 

107.6

 

105.9

 

101.6

 

135°

 

103.4

 

104.8

 

104

 

101.8

 

96.5

 

99.4

 

101.1

 

102.8

 

101.7

 

99.6

 

94.5

 

97.4

 

165°

 

103.4

 

103.5

 

103

 

103.3

 

103

 

91.6

 

101

 

101.4

 

100.8

 

101.1

 

100.2

 

89.4

 

 

Vertical Sound Output Max Voltage (54 Vdc) LAFmax,T dB(A)

 

Vertical Sound Output Min Voltage (11.5 Vdc) LAFmax,T dB(A)

 

Angle

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

Tone 44

 

Tone 8

 

Tone 2

 

Tone 21

 

Tone 31

 

Tone 5

 

15°

 

104.1

 

104.1

 

103.2

 

104.1

 

102.3

 

92.3

 

101.8

 

101.8

 

100.8

 

101.8

 

100

 

90.4

 

45°

 

103.4

 

106.4

 

105.2

 

101.9

 

96.3

 

100.2

 

101.3

 

104.3

 

103.1

 

99.7

 

94.1

 

98.2

 

75°

 

109.8

 

110.1

 

109.8

 

110.4

 

108.3

 

103.2

 

107.7

 

107.8

 

107.7

 

108.4

 

106.2

 

101.4

 

105°

 

109.1

 

109.9

 

109.5

 

110

 

108.3

 

102.9

 

106.9

 

107.7

 

107.1

 

107.6

 

105.7

 

101.3

 

135°

 

101.1

 

106.4

 

104.7

 

101.8

 

96.6

 

101

 

100.6

 

104.1

 

102.3

 

99.6

 

94.5

 

99.1

 

165°

 

103.6

 

103.1

 

102.8

 

103.6

 

102.8

 

91.8

 

101.2

 

100.9

 

100.7

 

101.4

 

99.8

 

89.8

 

Construction Product Regulation

 

• 

A112NDC024 is compliant to EN54

-

3:2001+A1+A2

 

• 

Alarm devices –

 

Sounder for use in fire detection and fire alarm systems installed in and 

around buildings 

 

• 

Type 4 / 4X / 3R / 13, IP66, Independently tested to EN60529:1991, (IP33C Compliant 
to EN54

-

3)

 

• 

Type B Product, For Indoor & Outdoor use

 

• 

Observe Precautions for handling electrostatic devices

 

• 

-

25°C to +55°C compliant to EN54

-

3

 

• 

Cable Glands must be suitably sealed and meet minimum IP33 for EN54

-

3 applications

 

• 

Storage Temperature: 

-

40°C to +70°C

 

• 

Maintenance –

 

None

 

• 

Mounting 

-

 Units can be mounted using the 2

-

off ø9mm holes in the mounting lugs or through the 

back of the housing using the supplied gasket seal.

 

2821

 

S36282

 

21

 

Order Code: A112NDC024

 

Voltage Range: 11.5

-

54Vdc

 

Nominal Voltage: 24Vdc 

 

Max Current: P1: 280mA @12Vdc;

 

 

P2: 430mA @24Vdc

 

DP

-

2821

-

CPR

-

0108

 

Summary of Contents for A112N

Page 1: ...Attenzione L installazione deve essere eseguita da un elettricista in conformità con i codici e le normative più recenti Atención La instalación debe ser realizada por un electricista de acuerdo con los últimos códigos y regulaciones Atenção A instalação deve ser realizada por um eletricista de acordo com os códigos e regulamentos mais recentes Внимание установка должна выполняться электриком в со...

Page 2: ...s com e2s com D221 00 001 IS Issue 1 10 05 2021 S2 S3 S2 S1 DC P1 P2 L N E C S2 S3 S2 S1 AC P1 P2 Default S2 Tone 1 Default S1 Tone 44 ON 1 OFF 0 AC DC See D221 95 001 DC Only see D221 06 001 H2 H1 ve switching Default H2 H1 ve switching Link W1 See D221 06 005 See D221 06 001 ...

Page 3: ...VICE MANUAL A112N AlertAlarm Sounder E2S Warning Signals Impress House Mansell Road Acton London W3 7QH sales e2s com e2s com D221 00 001 IS Issue 1 10 05 2021 4x 1Nm 190 7 48in 35 9 1 41in 35 9 1 41in 61 2 40in ø20mm ...

Page 4: ... Output Min Voltage 11 5 Vdc LAFmax T dB A Angle Tone 44 Tone 8 Tone 2 Tone 21 Tone 31 Tone 5 Tone 44 Tone 8 Tone 2 Tone 21 Tone 31 Tone 5 15 103 3 103 7 103 1 103 3 103 2 91 5 101 101 5 100 9 101 100 3 89 4 45 103 4 104 8 104 2 101 6 96 3 99 4 101 5 102 7 101 8 99 6 94 3 97 4 75 109 1 110 4 109 7 109 6 108 3 103 2 107 1 108 2 107 4 107 7 105 9 101 4 105 109 9 110 2 109 6 109 7 108 6 103 107 7 108...

Page 5: ...rating Current P1 Max Operat ing RMS P2 Nominal Operating Current P2 Max Operating RMS A112NDC024 12V dc 11 5 54V ac 280mA 280mA 376mA 430mA 24V dc 225mA 430mA 48V dc 122mA 223mA 115V ac 100 240V ac 50 60Hz 100mA 101mA A112NAC230 173mA 181mA 230V ac 65mA 105mA Max Operating current for worst case input voltage Nominal current at nominal voltage and Tone 44 The units have been tested and approved t...

Page 6: ... 0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 1 0 1 1 1 0 1 0 1 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 1 0 1 1 0 0 1 1 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 1 0 1 1 0 1 0 1 1 1 0...

Page 7: ...age Range Initial Peak Initial RMS A112NDC024 24V dc 11 5 54V dc P1 1455mA P2 1164mA P1 140mA P2 286mA A112NDC024 Sounder Directional Characteristics for Canadian Fire CAN ULC S525 at 10 feet Horizontal Axis Vertical Axis Angle OSPL Angle OSPL Angle OSPL Angle OSPL Ref 90 103 7 dB A Ref 90 103 7 dB A Ref 90 103 8 dB A Ref 90 103 78dB A 129 3 dB A 49 3 dB A 126 3 dB A 49 3 dB A 131 6 dB A 39 6 dB A...

Page 8: ...OTTS OF A112N A121 DC SOUNDER WIRING DIAGRAMS INTRODUCTION NTS 1 3 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Stage 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve R1...

Page 9: ... FOR STAGE OPERATION CUSTOMER SUPPLIED Stage 2 ve Common ve IN Common ve OUT Stage 1 ve OUT Stage 3 ve Stage 1 ve IN H2 H1 Stage 1 ve Stage 1 ve Stage 2 ve Stage 2 ve OF 2 3 R1 S2 S3 R1 S2 R2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Set H1 H2 to ve switch...

Page 10: ... E 7 8 6 5 D C 1 3 4 2 A B D221 06 001 R S RAIT B ISARD R N POTTS A112N A121 DC SOUNDER WIRING DIAGRAMS NTS Stage 1 ve Stage 1 ve Stage 2 ve Stage 2 ve OF 3 3 R1 R1 S2 R2 Two Stage Configuration Config 4 Line Stage Monitoring Use suitable monitoring relays modules Not to be used for reverse polarity monitoring Stage 1 Apply Power to Stage 1 ve Stage 1 ve Stage 2 Apply Power to Stage 2 ve Stage 2 v...

Page 11: ... 3 4 2 A B D221 06 005 R S RAIT B ISARD R N POTTS OF A112N A121 AC WIRING DIAGRAMS NTS 1 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 1 Earth Earth Stage 2 Stage 3 Common Live IN Live OUT Neutral IN Neutral OUT Earth Stage 1 Stage 2 Common N N L L E N N L L E C N N L L E C S2 S3 Live IN Live OUT Neutral IN Neutral OUT Stage 1 Live IN Stage 1 Live OUT Stage 1 Neutral IN Stage 1 Neutral OUT Single...

Page 12: ...Page left Intentionally blank ...

Reviews: