background image

 

 

 

 

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com 

www.e2s.com   DC-093_Issue_A (BExCP3) - Page 1 of 2 - QAF_252_Issue_5

 

UKCA Declaration of Conformity 

Manufacturer:   

 

European Safety Systems Ltd. 

 

 

 

Impress House, Mansell Road, Acton 

 

 

 

London, W3 7QH 

 

 

 

United Kingdom 

 

Equipment Type:  

 

BExCP3A-BG, BExCP3A-PB, BExCP3A-PT, BExCP3B-BG, BExCP3B-PB, BExCP3B-PT, 

 

 

 

BExCP3C-BG, BExCP3C-PB, BExCP3C-PT, BExCP3D-BG, BExCP3D-PB, BExCP3D-PT, 

 

 

 

BExCP3E-BG, BExCP3E-PB, BExCP3E-PT 

 

Directive  UKSI 2016:1107 (as amended by UKSI 2019:696) – Schedule 3A, Part 1 : Product or Protective System Intended for use in Potentially Explosive Atmospheres  
(UKCA) 

 

Notified Body for UK type Examination (Module B): 

Sira Certification Service 
Notified Body No.: 0518 

Rake Lane, Eccleston, Chester CH4 9JN, UK 

UK-type Examination Certificate (Module B): 

CSAE 21UKEX3556X 

Notified Body for Quality Assurance Notification / Conformity to EU-type 

based on 

quality assurance of the production process (Module D): 

Sira Certification Service 

Notified Body No.: 0518 

Rake Lane, Eccleston, Chester CH4 9JN, UK 

Quality Assurance Notification (Module D): 

CSAE 22UKQAN0046 

Provisions fulfilled by the equipment:                                         BExCP3A: 
 

 

                                                                                                            BExCP3B: 
 

 
                                                                                                            BExCP3C: 

 

 
                                                                                                            BExCP3D: 

 

 
                                                                                                            BExCP3E: 

II 2G Ex db eb IIC T6 Gb (-40°C ≤ Ta ≤ +70°C) 
II 2D Ex tb IIIC T75°C Db (-40°C ≤ Ta ≤ +70°C) 

or 

II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +50°C) 
II 2D Ex tb IIIC T60°C Db (-40°C ≤ Ta ≤ +50°C) 

or 
II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +65°C) 

II 2D Ex tb IIIC T75°C Db (-40°C ≤ Ta ≤ +65°C) 

or 
II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +70°C) 

II 2D Ex tb IIIC T80°C Db (-40°C ≤ Ta ≤ +70°C) 

or 
II 2G Ex db eb mb IIC T4 Gb (-40°C ≤ Ta ≤ +65°C) 

II 2D Ex tb IIIC T75°C Db (-40°C ≤ Ta ≤ +65°C) 
 

Standards applied: 

EN IEC 60079-0:2018 
EN 60079-1:2014 

EN 60079-7:2015/A1:2108 
IEC 60079-18:2015/AC:2018 

EN 60079-31: 2014 

IP6X Dust Protection to EN60079-0 / EN 60079-31 

Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)  

Standards applied: 

EN 61000-6-1:2007 

EN 61000-6-2:2005 

EN 61000-6-3:2007 / A1:2011 / AC: 2012 
EN 61000-6-4:2007 / A1:2011 

Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic 
equipment, including amendment by Directive 2015/863/EU. 

Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) 

The product and all the components contained within it are free from substances of very high concern. 

 

Summary of Contents for BExCP3D-PB

Page 1: ...P3BPB000001 Or 20 1CP3DPB000001 Or 20 1CP3EPB000001 WARNING DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT 3 Type Approval Standards The beacon has an EC Type examination certificate issued b...

Page 2: ...to 4 0mm For the 8 way DIN rail wire sizes allowable are 0 5mm to 2 5mm Leads connected to the terminals shall be insulated for the appropriate voltage and this insulation shall extend to within 1mm...

Page 3: ...re fault tolerance of 0 at SIL 2 The product was assessed against failure modes Failure to close a contact when the call point is struck with specified force Failure to open a contact when the call po...

Page 4: ...perated condition Unoperated condition Glass Intact Standby Condition Terminals 2 3 4 5 open Terminals 2 3 6 closed Operated condition Glass Broken Button pushed in Terminals 2 3 4 5 closed Terminals...

Page 5: ...nds B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment BExCP3A BExCP3B BExCP3C BExCP3D BExCP3E II 2G Ex db...

Page 6: ...y high concern Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure rated IP66 Construction and design requirements according to EN54 11...

Page 7: ...CP3A BExCP3B BExCP3C BExCP3D BExCP3E II 2G Ex db eb IIC T6 Gb 40 C Ta 70 C II 2D Ex tb IIIC T75 C Db 40 C Ta 70 C or II 2G Ex db eb mb IIC T4 Gb 40 C Ta 50 C II 2D Ex tb IIIC T60 C Db 40 C Ta 50 C or...

Page 8: ...d by enclosures IP code enclosure rated IP66 Construction and design requirements according to EN54 11 2001 clause 4 7 BExCP3A BG B BG C BG D BG only fitted with burning house symbol shown in figure 3...