TONE SELECTION TABLE  

Note Switch No. 6 is not used 

 
 

 
 

16) 

CAUTION!  -  Ensure  correct  orientation  of 
Beacon  Housing  onto  Sounder  housing  when 
closing unit

 

 

Please  note  that  due  to  the  tight  spacing  internally  the 
Beacon housing can only be closed in one orientation relative 
to the Sounder housing, otherwise PCB boards may become 
damaged. 
 
The M20 entries on the Beacon housing must be aligned with 
the  product  labels  on  the  side  of  the  Sounder  housing  (both 
M20 entries and labels on the same side). 

 
 
 
 
 
 
 
 
 
 
 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

 

Tone Selection 

DIP Switch                                    
Settings 

Stage 1 

Frequency Description 

1    2   3   4   5 
 

Continuous  1000Hz  

Toxic gas alarm 

0    0   0   0   0 

Alternating 

800/1000Hz 

at 

0.25s 

intervals 

1    0   0   0   0 

Slow  Whoop  500/1200Hz  at  0.3Hz 
with 0.5s gap repeated 

0    1   0   0   0 

Sweeping 800/1000 at 1Hz 

1    1   0   0   0 

Continuous at 2400Hz 

0    0   1   0   0 

Sweeping 2400/2900Hz at 7Hz 

1    0   1   0   0 

Sweeping 2400/2900Hz at 1Hz 

0    1   1   0   0 

Siren 500/1200/500Hz at 0.3Hz 

1    1   1   0   0 

Sawtooth 1200/500Hz at 1Hz 

0    0   0   1   0 

10 

Alternating 2400/2900Hz at 2Hz 

1    0   0   1   0 

11 

Intermittent  1000Hz  at  0.5Hz 

General 

alarm

 

0    1   0   1   0 

12 

Alternating 800/1000Hz at 0.875Hz 

1    1   0   1   0 

13 

Intermittent 2400Hz at 1Hz 

0    0   1   1   0 

14 

Intermittent 800Hz 0.25s on 1s off 

1    0   1   1   0 

15 

Continuous at 800Hz 

0    1   1   1   0 

16 

Intermittent  660Hz  150mS  on,  150mS 
off 

1    1   1   1   0 

17 

Alternating 544Hz  
(100mS)/440Hz(400mS) 

0    0   0   0   1 

18 

Intermittent 660Hz 1.8s on, 1.8s off 

1    0   0   0   1 

19 

1400Hz to 1600Hz sweep up over 1s - 
1600Hz  to  1400Hz  sweep  down    over 
0.5s 

0    1   0   0   1 

20 

Continuous 660Hz  

1    1   0   0   1 

21 

Alternating 554/440Hz at 1Hz 

0    0   1   0   1 

22 

Intermittent 554Hz at 0.875Hz 

1    0   1   0   1 

23 

800Hz pulsing at 2Hz 

0    1   1   0   1 

24 

Sweeping 800/1000Hz at 50Hz 

1    1   1   0   1 

25 

Sweeping 2400/2900Hz at 50Hz 

0    0   0   1   1 

26 

Simulated bell sound 

1    0   0   1   1 

27 

Continuous 554Hz 

0    1   0   1   1 

28 

Continuous 440Hz 

1    1   0   1   1 

29 

Sweeping 800/1000Hz at 7Hz 

0    0   1   1   1 

30 

420Hz repeating 0.625s on, 0.625s off  

Australian alert signal

 

1    0   1   1   1 

31 

1200/500Hz at 1 Hz  

Prepare to abandon platform 

0    1   1   1   1 

32 

Sweeping 500/1200Hz 3.75s on, 0.25s 
off 15Hz 

1    1   1   1   1 

 

Customer Connection 
Power Supply Wires 
-ve to Beacon, +ve to 
Telephone PCB 

BExDCTS110-05D  DC Wiring Diagram 

BExDCTS110-05D  AC Wiring Diagram 

Sounder & 
Telephone 
Section 

Beacon Section 

Sounder & 
Telephone 
Section 

Customer Connection 
Power Supply Wires 
N to Beacon, L to 
Telephone PCB 

Figure 8 

Figure 9 

Beacon Section 

Summary of Contents for BExDCTS110-05D

Page 1: ... DUST ATMOSPHERE IS PRESENT COVER BOLTS CLASS A4 80 USE HEAT RESISTING CABLES AND CABLEGLANDS Rated 110ºC AT AMB TEMPERATURES OVER 40ºC Year of Construction Serial No i e 10 1DCTS21000001 3 Type Approval Standards The units have an EC Type examination certificate issued by DEKRA and have been approved to the following standards EN60079 0 2006 IEC60079 0 2004 Ed4 General Requirements EN60079 1 2007...

Page 2: ...that these screws and their spring washers are kept in a safe place during installation On completion of the cable wiring installation the flameproof joints should be inspected to ensure that they are clean and that they have not been damaged during installation Also check that the earth bonding wire between the two casting sections is secure and the O ring seal is in place When replacing the beac...

Page 3: ...tries which have an M20 x 1 5 entry thread as standard Only cable glands approved for Ex d applications can be used which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN 60079 14 2008 IEC60079 14 2007 When only one cable entry is used the other one must be closed with an Ex d flameproof blanking plug which must be sui...

Page 4: ...elephone pcb see figures 6 and 7 The Telephone Selection Table on page six shows the switch positions 1 4 for the country setting and switch 5 for the beacon continuous or pulse mode and switch 6 for the sounder continuous or pulse mode When making any changes to the country selection the unit needs to be de energised for a minimum of 2 minutes for the changes to take effect When pulse mode of ope...

Page 5: ... 1200 500Hz at 0 3Hz 1 1 1 0 0 9 Sawtooth 1200 500Hz at 1Hz 0 0 0 1 0 10 Alternating 2400 2900Hz at 2Hz 1 0 0 1 0 11 Intermittent 1000Hz at 0 5Hz General alarm 0 1 0 1 0 12 Alternating 800 1000Hz at 0 875Hz 1 1 0 1 0 13 Intermittent 2400Hz at 1Hz 0 0 1 1 0 14 Intermittent 800Hz 0 25s on 1s off 1 0 1 1 0 15 Continuous at 800Hz 0 1 1 1 0 16 Intermittent 660Hz 150mS on 150mS off 1 1 1 1 0 17 Alternat...

Page 6: ...D CONTINUOUS OR PULSE SELECTION TABLE Telephone Selection Settings DIP Switch Settings DIP Switch Settings Dialing Country Setting 1 2 3 4 5 6 Australia Ireland New Zealand Singapore South Africa UK 0 0 0 0 Belgium Canada Cyprus Hong Kong Spain Turkey USA 1 0 0 0 Czech Republic Finland France Germany Greece Italy Luxemburg Netherlands Norway Switzerland 0 1 0 0 Austria Iceland Portugal Sweden 1 1 ...

Reviews: