background image

E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH    

sales@e2s.com          e2s.com      

Page 1  of 1

D210-95-651-IS_Issue_A - 16/01/2023

SIL 2 

Approved
Tone

Tone Description

Tone 
Visual

Stage 1

DIP SW 1

 Settings

1 2 3 4 5 6

Stage

2

Continuous1000Hz Toxic Gas Alarm

0 0 0 0 0 0

1

11

Alternating 800/1000Hz at 0.25s Intervals

1 0 0 0 0 0

17

5

Slow Whoop 500/1200Hz at 0.3Hz with

0 1 0 0 0 0 

5

 0.5s gap repeated

Sweeping 800/1000Hz at 1Hz

1 1 0 0 0 0

6

5

Continuous at 2400Hz

0 0 1 0 0 0

3

27

Sweeping 2400/2900Hz at 7Hz

1 0 1 0 0 0

7

5

Sweeping 2400/2900Hz at 1Hz

0 1 1 0 0 0

10

5

Siren 500/1200/500Hz at 0.3Hz

1 1 1 0 0 0

2

5

Sawtooth 1200/500Hz at 1Hz

0 0 0 1 0 0

15

2

Alternating 2400/2900Hz at 2Hz

1 0 0 1 0 0

7

5

Intermittent 1000Hz at 0.5Hz General Alarm

0 1 0 1 0 0

31

1

Alternating 800/1000Hz at 0.875Hz

1 1 0 1 0 0

4

5

Intermittent 2400Hz at 1Hz

0 0 1 1 0 0

15

5

Intermittent 800Hz 0.25s on 1s off

1 0 1 1 0 0 

4

5

Continuous at 800Hz

0 1 1 1 0 0 

2

5

Intermittent 660Hz 150mS on, 150mS off

1 1 1 1 0 0 

18

5

Alternating 544Hz (100mS)/440Hz(400mS)

0 0 0 0 1 0 

2

27

Intermittent 660Hz 1.8s on, 1.8s off

1 0 0 0 1 0

2

5

1400Hz to 1600Hz sweeep up over 1s 

0 1 0 0 1 0 

2

5

- 1600Hz to 1400Hz sweep down over 0.5s

Continuous 660Hz

1 1 0 0 1 0 

2

5

Alternating 554/440Hz at 1Hz

0 0 1 0 1 0

2

5

Intermittent 554Hz at 0.875Hz

1 0 1 0 1 0 

2

5

800Hz pulsing at 2Hz

0 1 1 0 1 0 

6

5

Sweeping 800/1000Hz at 50Hz

1 1 1 0 1 0

29

5

Sweeping 2400/2900Hz at 50Hz

0 0 0 1 1 0 

29

5

Simulated Bell Sound

1 0 0 1 1 0 

2

1

Continuous 554Hz

0 1 0 1 1 0 

26

5

Continuous 440Hz

1 1 0 1 1 0

2

5

Sweeping 800/1000Hz at 7Hz

0 0 1 1 1 0 

7

5

420Hz repeating 0.625s on, 0.625s off 

1 0 1 1 1 0 

32

5

Austrailian Alert Signal

1200/500Hz at 1Hz Prepare to 

0 1 1 1 1 0

11

1

Abandon Platform

Sweeping 500/1200Hz 

0 0 0 0 0 1

26

1

3.75s on, 0.25s off 15Hz

Stage

3

1000Hz

f1(Hz)

a(s)

a(s)

f(Hz)

1200Hz

0.5s

500Hz

3.3s

1000Hz

1s

800Hz

2400Hz

800Hz

660Hz

554Hz

440Hz

0.14s

2900Hz

1s

2400Hz

2900Hz

2400Hz

2900Hz

0.02s

2400Hz

1000Hz

0.02s

800Hz

1000Hz

0.14s

800Hz

1200Hz

0.25s

500Hz

3.75s

1200Hz

500Hz

1s

420Hz

0.625s

0.625s

1450Hz

0.25s

0.69ms

800Hz

0.5s

0.5s

660Hz

150ms

150ms

660Hz

1.8s

1.8s

554Hz

1.14s

1.14s

800Hz

0.25s

1s

2400Hz

0.5

0.5s

1000Hz

1s

1s

2900Hz

2400Hz

1600Hz

1s

1400Hz

0.5s

1000HZ

1.14s

800Hz

1.14s

0.25s

0.25s

540Hz

440Hz

400ms

100ms

540Hz

440Hz

0.5s

0.5s

1200Hz

3.33s

500Hz

500Hz

1200Hz

1s

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

27

26

28

29

30

31

32

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

No

No

No

No

No

Stage 1
Set DIP
SW 1
Tone No.

Summary of Contents for BExS110D-SIL

Page 1: ...e table shows the input current taken by the various sounders The current levels shown above are for the 440Hz Continuous tone nominal input voltage Nominal current at nominal voltage Table 1 Electric...

Page 2: ...mixture likely to occur in normal operation Zone 2 Explosive gas air mixture not likely to occur in normal operation and if it does it will only exist for a short time Gas Groupings Group IIA Propane...

Page 3: ...ure and the O ring seal is in place When replacing the flameproof cover casting ensure that it is square with the flameproof chamber casting before inserting Carefully push the cover in place allowing...

Page 4: ...in the flameproof enclosure See section 7 of this manual for access to the flameproof enclosure Wires having a cross sectional area between 0 5 mm to 2 5mm can be connected to each terminal way If an...

Page 5: ...pattern generation and signal output checks Default Tone 1 0 0 0 0 0 0 ON 1 OFF 0 Figure 7 DIP switch configuration Refer to D210 95 651 IS Tone Table for tone selection Table 2 below is a summary of...

Page 6: ...ndby mode and Active mode Health status of power supply Sounder correct function and tone pattern The SIL 2 sounder operates as part of a SIL 2 system The sounder will after commissioning remain power...

Page 7: ...ase contact your local E2S representative Commissioning System Functional start up of System Normally in reverse polarity mode When Commissioning system the power must not be disrupted to the SIL 2 Un...

Page 8: ...sounder check on pattern generation and signal output checks Important Only tones use tones that are stated as SIL 2 approved for the SIL 2 application Ensure that the unit is set to one of these tone...

Page 9: ...he circuit Note a cable short circuit will not be detectable in this configuration For one unit only Sounder power supply terminal block Current drawn mA Active Mode 190mA Standby Mode 25mA SIL2 TB1 C...

Page 10: ...ts and faults occur If multiple SIL 2 alarm horn sounders are to be cabled in series the monitoring connections differ from that of a single alarm horn sounder For more information see manual D197 00...

Page 11: ...pins 2 3 linked Places power supply terminal Fault resistor RLY 1 2 in circuit As used in 2 Wire Configuration Figure 13 J2 Header pin positions Fault Resistor FR 18 4 SIL 2 Hard Reset Function Power...

Page 12: ...sound output despite no input BExS110D SIL Failure to Sound Integrity in respect of failure to release SIL 2 Total Failure rate 0 304 pmh hazardous failure rate revealed 0 233 pmh hazardous failure r...

Page 13: ...9 k CSR Current Sense Resistor is E 2 7 k EOL End Of Line resistor is F 3 3 k Two digit resistor coding on other units BExS110DFDC024AB1S1R AZ Where the FR Fault Resistor is A 2 2 k EOL End Of Line r...

Page 14: ...n over 0 5s Continuous 660Hz 1 1 0 0 1 0 2 5 Alternating 554 440Hz at 1Hz 0 0 1 0 1 0 2 5 Intermittent 554Hz at 0 875Hz 1 0 1 0 1 0 2 5 800Hz pulsing at 2Hz 0 1 1 0 1 0 6 5 Sweeping 800 1000Hz at 50Hz...

Page 15: ...e 1 ve Stage 1 ve For full 4 Wire SIL 2 Connection Monitor SIL 2 ve and SIL 2 ve Terminals 1 2 in RLY1 2 Two or Three Stage Configuration Config 1b Line Monitoring Common Positive Header pins set to n...

Page 16: ...oup Netherlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIB or IIC T4 Gb II 2G Ex db...

Page 17: ...are in accordance with the restriction of the use of hazardous substances in electrical and electronic equipment including amendment by Directive 2015 863 EU Regulation EC 1907 2006 Registration Evalu...

Page 18: ...duction process Module D Sira Certification Service Notified Body No 0518 Rake Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the eq...

Page 19: ...and Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Reviews: