European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           sales@e-2-s.com              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e-2-s.com             Fax: +44 (0)208 740 4200 
Document No. IS 2462-P      Issue E        12-03-10                                   Sheet 1 of 3

 

INSTRUCTION MANUAL (ATEX / IECEx) 

BExTBG05D   Flameproof Flashtel 

For use in Flammable Gas and Dust 

Atmospheres

 
 
 
 

1)  Introduction 

 
The BExTBG05D is a flameproof Flashtel which is certified to 

meet  the  requirements  of  the  ATEX  directive  94/9/EC  and 
IECEx  scheme.  The  Flashtel  produces  a  visual  warning 

signal when triggered by a telephone ringing signal and can 
be used in hazardous areas where potentially flammable gas 

and dust atmospheres may be present. The BExTBG05D has 
a  flash  energy  level of  5  joules  and can  be  used  in  Zone  1 
and Zone 2 areas with gases in groups IIA, IIB and IIC and 

Temperature  Classifications  of  T1,  T2,  T3  andT4.  The  unit 
can  also  be  used  in  a  temperature  classification  T5,  if  the 

upper  ambient  temperature  is  restricted  to  +55ºC  and  T6  if 
the  upper  ambient  temperature  is  restricted  to  +40ºC.  The 

unit  can  be  used  in  Zone  21  and  Zone  22  areas  for 
combustible dusts and has an IP rating of IP 67 and a surface 

temperature rating of T110ºC or T95ºC if the upper ambient 
temperature  is  restricted  to  +55ºC  and  T85ºC  if  the  upper 
ambient temperature is restricted to +40ºC. 

 

2)  Marking 

 

All  units  have  a  rating  label,  which  carries  the  following 
important information:- 

 
Unit Type No.    

BExTBG05D

 

 

Input Voltage:      230V  or 115V 
 
Codes:    

Ex d IIC T4 for Ta –50ºC to +70ºC 

Ex d IIC T5 for Ta –50ºC to +55ºC 

 

Ex d IIC T6 for Ta –50ºC to +40ºC

 

  

Ex tD A21 IP67 T115ºC based on max. Ta of +70ºC 

 
Certificate No’s

    KEMA 00ATEX2006 

 

 

IECEx KEM 10.0002

 

 

        

 

 

 

 

 

 

“Warnings” 

 

DO NOT OPEN WHEN AN EXPLOSIVE  

                              GAS OR DUST ATMOSPHERE IS PRESENT 
 

      COVER BOLTS CLASS A4-80 

 
 

 USE HEAT RESISTING CABLES AND CABLE GLANDS 

  

(Rated 110ºC) AT AMB. TEMPERATURES OVER 40ºC 

 

Year of Construction /  
Serial No.       

 

 i.e.  

10

 / 

1DTB1300001

 

 

3) 

Type Approval Standards

 

 

The  Flashtel  has  EC  Type  Examination  and  IECEx 
certificates  issued by  KEMA  and  has  been  approved  to  the 

following standards:- 

 
 

 
 
 

 

 
EN60079-0:2006   IEC60079-0:2004 (Ed4)

      

General Requirements

 

EN60079-1:2007   IEC60079-1:2007

 

(Ed6)

        Flameproof Enclosure ‘d’ 

 
EN61241-0:2006   IEC61241-0:2004 (Ed1)       Dust General 

          Requirements 

EN61241-1:2004   IEC60079-1:2004 (Ed1)       Dust Enclosures tD 
 

4) 

Installation Requirements

 

 

The Flashtel  must  be  installed  in  accordance  with  the  latest 
issues of the relevant parts of the EN60079 standards or the 
equivalent  IEC  standards  –  Selection,  Installation  and 

maintenance  of  electrical  apparatus  for  use  in  potentially 
explosive  atmospheres  (other  than  mining  applications  or 

explosive processing and manufacture):- 
 

EN60079-14:2008

    

Electrical Installations in Hazardous 

IEC60079-14:2007 (Ed4) 

Areas (other than mines)

 

 

EN60079-10:2003

   

Classification of Hazardous Areas

 

IEC60079-10:2008 (Ed1) 

 

The installation of the units must also be in accordance with 
any  local  codes  that  may  apply  and  should  only  be  carried 

out  by  a  competent  electrical  engineer  who  has  the 
necessary training. 

 

5) 

Zones,  Gas  Group,  Category,  IP  Rating  and 
Temperature Classification 

 

The BExTBG05D beacons have been certified Ex d IIC T4 for 
Ta –50ºC to +70ºC, Ex d IIC T5 for Ta –50ºC to +55ºC and 

Ex d IIC T6 for Ta –50ºC to +40ºC for gas and IP67 T115ºC 
based  on  max.  Ta  of  +70ºC  for  dust.  This  means  that  the 

units  can  be  installed  in  locations  with  the  following 
conditions:- 

 

Area Classification Gas: 

 

Zone 1 

Explosive  gas  air  mixture  likely  to  occur  in 

normal operation. 

Zone 2 

Explosive  gas  air  mixture  not  likely  to  occur, 

and if it does, it will only exist for a short time. 

  

Gas Groupings: 

 

Group IIA 

Propane 

Group IIB 

Ethylene 

Group IIC 

Hydrogen and Acetylene 

  

Temperature Classification: 

 

T1 

400

o

 C  

T2 

300

o

 C 

T3 

200

o

 C 

T4 

135

o

 C 

 

T5 

100

o

 C 

Amb. +55ºC 

T6 

85

o

 C 

Amb. +40ºC 

 

0518 

II 2G/D 

Epsilon x 

Equipment Group and 
Category: 

CE Marking 
Notified Body No. 