Document No. IS 2462-P Issue E 12-03-10 Sheet 1 of 3
INSTRUCTION MANUAL (ATEX / IECEx)
BExTBG05D Flameproof Flashtel
For use in Flammable Gas and Dust
Atmospheres
1) Introduction
The BExTBG05D is a flameproof Flashtel which is certified to
meet the requirements of the ATEX directive 94/9/EC and
IECEx scheme. The Flashtel produces a visual warning
signal when triggered by a telephone ringing signal and can
be used in hazardous areas where potentially flammable gas
and dust atmospheres may be present. The BExTBG05D has
a flash energy level of 5 joules and can be used in Zone 1
and Zone 2 areas with gases in groups IIA, IIB and IIC and
Temperature Classifications of T1, T2, T3 andT4. The unit
can also be used in a temperature classification T5, if the
upper ambient temperature is restricted to +55ºC and T6 if
the upper ambient temperature is restricted to +40ºC. The
unit can be used in Zone 21 and Zone 22 areas for
combustible dusts and has an IP rating of IP 67 and a surface
temperature rating of T110ºC or T95ºC if the upper ambient
temperature is restricted to +55ºC and T85ºC if the upper
ambient temperature is restricted to +40ºC.
2) Marking
All units have a rating label, which carries the following
important information:-
Unit Type No.
BExTBG05D
Input Voltage: 230V or 115V
Codes:
Ex d IIC T4 for Ta –50ºC to +70ºC
Ex d IIC T5 for Ta –50ºC to +55ºC
Ex d IIC T6 for Ta –50ºC to +40ºC
Ex tD A21 IP67 T115ºC based on max. Ta of +70ºC
Certificate No’s
KEMA 00ATEX2006
IECEx KEM 10.0002
“Warnings”
DO NOT OPEN WHEN AN EXPLOSIVE
GAS OR DUST ATMOSPHERE IS PRESENT
COVER BOLTS CLASS A4-80
USE HEAT RESISTING CABLES AND CABLE GLANDS
(Rated 110ºC) AT AMB. TEMPERATURES OVER 40ºC
Year of Construction /
Serial No.
i.e.
10
/
1DTB1300001
3)
Type Approval Standards
The Flashtel has EC Type Examination and IECEx
certificates issued by KEMA and has been approved to the
following standards:-
EN60079-0:2006 IEC60079-0:2004 (Ed4)
General Requirements
EN60079-1:2007 IEC60079-1:2007
(Ed6)
Flameproof Enclosure ‘d’
EN61241-0:2006 IEC61241-0:2004 (Ed1) Dust General
Requirements
EN61241-1:2004 IEC60079-1:2004 (Ed1) Dust Enclosures tD
4)
Installation Requirements
The Flashtel must be installed in accordance with the latest
issues of the relevant parts of the EN60079 standards or the
equivalent IEC standards – Selection, Installation and
maintenance of electrical apparatus for use in potentially
explosive atmospheres (other than mining applications or
explosive processing and manufacture):-
EN60079-14:2008
Electrical Installations in Hazardous
IEC60079-14:2007 (Ed4)
Areas (other than mines)
EN60079-10:2003
Classification of Hazardous Areas
IEC60079-10:2008 (Ed1)
The installation of the units must also be in accordance with
any local codes that may apply and should only be carried
out by a competent electrical engineer who has the
necessary training.
5)
Zones, Gas Group, Category, IP Rating and
Temperature Classification
The BExTBG05D beacons have been certified Ex d IIC T4 for
Ta –50ºC to +70ºC, Ex d IIC T5 for Ta –50ºC to +55ºC and
Ex d IIC T6 for Ta –50ºC to +40ºC for gas and IP67 T115ºC
based on max. Ta of +70ºC for dust. This means that the
units can be installed in locations with the following
conditions:-
Area Classification Gas:
Zone 1
Explosive gas air mixture likely to occur in
normal operation.
Zone 2
Explosive gas air mixture not likely to occur,
and if it does, it will only exist for a short time.
Gas Groupings:
Group IIA
Propane
Group IIB
Ethylene
Group IIC
Hydrogen and Acetylene
Temperature Classification:
T1
400
o
C
T2
300
o
C
T3
200
o
C
T4
135
o
C
T5
100
o
C
Amb. +55ºC
T6
85
o
C
Amb. +40ºC
0518
II 2G/D
Epsilon x
Equipment Group and
Category:
CE Marking
Notified Body No.