European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D190-00-671-IS
Issue 2
06-03-2023
Sheet 5 of 15
9)
Settings
Following illustrations show the settings available for D1xS2 Alarm
Horn Sounders. See schematic diagram D190-06-651 for details.
9.1. Configuration
See Table 1 for product power supply and Sound Pressure Levels
(SPL).
Configuration for DC Units
Fig 5: DC PCBA.
9.2. Stage Switching Polarity (DC Units)
Switching from positive switching (default) to negative switching - DC
Only.
NOTE:
Max supply is 33V DC
–
if higher DC voltage is required, use
Negative switching.
Fig 6: Stage Switching Polarity
.
9.3. Tone Selection
The D1x Alarm Horn Sounders have 64 different tones that can be
selected independently for the first and second stage alarms. The
tones are selected by operation of the tone setting DIP switch 1 & DIP
switch 2 (see fig 7) on the PCB, for stage 1 and stage 2 respectively.
Default = Switch 2
S2 - Tone 1
0 0 0 0 0 0
Default = Switch 1
S1
–
Tone 44
1 1 0 1 0 1
(ON = 1, OFF = 0)
Figure 7: DIP switch configuration
The sounder can also be switched to sound the third and fourth stage
alarm tones.
The tone table (D221-95-651-IS) shows the switch positions for the 64
tones on first and second stages and which tones are available for the
third and fourth stages dependent on the Stage 1 DIP switch setting.
Following table (Table 3) is a summary of DC: D190-06-651 for wiring
options.
(default)