background image

INSTRUCTION MANUAL 

D2xL1 & D2xL2 
Loudspeaker

 

Class I, Zone 2 & 22

 

 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D252-00-201-IS

 

Issue 1

 

21-12-2023

 

 

Sheet 1 of 5

 

 

 
 

 

 

D2xL1F 

D2xL2F 

D2xL2H 

1) 

Product Table 

 

 

2) 

Warnings 

 

 

 
 
DO  NOT  OPEN  WHEN  AN  EXPLOSIVE  ATMOSPHERE  IS 
PRESENT  
DO NOT OPEN WHEN ENERGISED  
POTENTIAL  ELECTROSTATIC  CHARGING  HAZARD  -  CLEAN 
ONLY WITH A DAMP CLOTH  
 
NE PAS OUVRIR UN PRESENCE D’ATMOSPHERE EXPLOSIVE  
NE PAS OUVRIR ENERGIE  
DANGER POTENTIEL CHARGE ÉLECTROSTATIQUE - NETTOYER 
UNIQUEMENT AVEC UN CHIFFON HUMIDE  
 
 
 
 
 
 
 
 

 

3) 

Marking & Rating Information 

 

3.1 

UL Certification 

 
All Loudspeakers comply with the following standards: 
 
UL 1480A (Ed 1) 

– Speakers for Commercial and Professional Use 

CSA C22.2 No. 205 (Ed 3) 

– Signal Equipment 

UL  1480  (Ed  6) 

–  Speakers  for  Fire  Alarm  and  Signaling  Systems, 

Including Accessories 
CAN/ULC-S541  (Ed  4) 

–  Speakers  for  Fire  Alarm  and  Signaling 

Systems, Including Accessories 
 
See relevant sections further down. 
 
The  D2xL  Loudspeakers  comply  with  the  following  standards  for 
hazardous locations: 
 
 
 
 
 
 

Unit Type Code 

Input  

Power (Watts) 

Max I/P Volts 

Sound 

Pressure Level 

dB(A) 

Max 

Rated 

Pink 

Noise 
@ 1W 

D2xL1FV100-A 

100V Line 

15 

100 

120 

101 

D2xL1FV725-A 

70.7 / 25V Line 

15 

70.7 

D2xL1FR008-A 

8 Ohm 

15 

10.95 

D2xL1FR016-A 

16 Ohm 

15 

15.49 

D2xL2FV100-A 

100V Line 

25 

100 

124 

104 

D2xL2FV725-A 

70.7 / 25V Line 

25 

70.7 

D2xL2FR008-A 

8 Ohm 

25 

14.14 

D2xL2FR016-A 

16 Ohm 

25 

20 

D2xL2HV100-A 

100V Line 

25 

100 

129 

106 

D2xL2HV725-A 

70.7 / 25V Line 

25 

70.7 

D2xL2HR008-A 

8 Ohm 

25 

14.14 

D2xL2HR016-A 

16 Ohm 

25 

20 

Frequency Range: 400Hz to 8000Hz 

 

The table shows the input current taken by the various Loudspeakers. 
 
Nominal current at nominal voltage. 

Table 1: Electrical Ratings. 

Summary of Contents for D2xL1 Series

Page 1: ...205 Ed 3 Signal Equipment UL 1480 Ed 6 Speakers for Fire Alarm and Signaling Systems Including Accessories CAN ULC S541 Ed 4 Speakers for Fire Alarm and Signaling Systems Including Accessories See rel...

Page 2: ...o 75 C Zone 22 AEx tc IIIC T119 C Dc Ta 55 C to 75 CEC Class Zone Ratings for Canada Standards CSA C22 2 No 60079 0 Ed 4 CSA C22 2 No 60079 7 Ed 2 CSA C22 2 No 60079 31 Ed 2 Model No Rating D2xL1 V100...

Page 3: ...e of the following standards EN60079 14 IEC60079 14 Explosive atmospheres Electrical installations design selection and erection EN60079 10 1 IEC60079 10 1 Explosive atmospheres Classification of area...

Page 4: ...st only be installed by suitably qualified personnel in accordance with the latest issues of the relevant standards The installation of the units must also be in accordance with the NEC CEC and any lo...

Page 5: ...into account when selecting the value of the end of line monitoring resistance The resistor must be connected directly across the terminals Whilst keeping its leads as short as possible a spacing of a...

Page 6: ...the 3 off 4 off 7mm holes in the mounting bracket The Equipment must not be installed with the horn facing upwards of horizontal If a high IP Ingress Protection rating is required then a suitable sea...

Page 7: ...D2xL2HR008 8 Ohm 25W 14 14V 105 18 D2xL2HR016 16 Ohm 25W 20 00V 104 92 CAN ULC S541 Directional Characteristics Unit Type ode Rated Angle Horizontal Axis Vertical Axis 3dB A 6dB A Reduction 90 3dB A...

Page 8: ...IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D252 06 201 D HOWGILL R N POTTS R N POTTS 18 11 20 OF NTS 1 5 1 INTRODUCTION RSR 12 10...

Page 9: ...OUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D252 06 201 D HOWGILL R N POTTS R N POTTS 18 11 20 OF NTS 2 5 18 11 20 18 11 20 D2xL1 D2xL2 L...

Page 10: ...L TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT...

Page 11: ...4 5 18 11 20 18 11 20 D2xL1 D2xL2 LINE IN LOW IMPEDANCE LOUDSPEAKER WIRING DIAGRAMS D2xL1 D2xL2 ve ve COM A B D2xL1V725 Line in Config 4a Optional Line Monitoring 15W 25V Apply Signal to Common A 70V...

Page 12: ...L1 D2xL2 D2xL2V725 Line in Config 5a Optional Line Monitoring 25W 25V Apply Signal to Common A 70V Apply Signal to Common C OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED MINIMUM VALUE R1 D2xL2V7...

Page 13: ...urance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812...

Page 14: ...the components contained within it are free from substances of very high concern Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure r...

Page 15: ...Assurance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 0518 Rake Lane Eccleston Chester CH4 9JN UK Quali...

Page 16: ...e components contained within it are free from substances of very high concern Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure rate...

Reviews: