European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D252-00-201-IS
Issue 1
21-12-2023
Sheet 3 of 5
4)
Zones, Gas Group, Category and Temperature
Classification
The units can be installed in locations with the following conditions:
Area Classification Gas
Zone 2
Explosive gas air mixture not likely to occur in
normal operation, and if it does, it will only exist for
a short time.
Gas Groupings
Group IIA
Propane
Group IIB
Ethylene
Group IIC
Hydrogen and Acetylene
Temperature Classification for Gas Applications
T1
450
o
C
T2
300
o
C
T3
200
o
C
T4
135
o
C (D2xL1 only up to 50°C)
Area Classification Dust
Zone 22
Explosive dust air mixture not likely to occur in
normal operation, and if it does, it will only exist for
a short time.
Dust Groupings
Group IIIA
Combustible Dusts
Group IIIB
Non-Conductive Dusts
Group IIIC
Conductive Dusts
Equipment Category
3G, 3D
Equipment Protection Level
Gc, Dc
Maximum Surface Temperature for Dust Applications
109°C (D2xL1)
119°C (D2xL2)
Ambient Temperature Range
-55°C to +75°C (-67°F to +167°F)
IP Rating
IP66/67 to EN60529
4 / 4X / 3R / 13 to UL50E / NEMA250
Installation must be carried out in compliance with the latest issue of the
following standards:
EN60079-14 / IEC60079-14: Explosive atmospheres - Electrical
installations design, selection and erection
EN60079-10-1 / IEC60079-10-1: Explosive atmospheres - Classification of
areas. Explosive gas atmospheres
EN60079-10-2 / IEC60079-10-2: Explosive atmospheres - Classification of
areas. Explosive dust atmospheres
5)
Specific Conditions of Installation
The plastic horn is not anti-static and the metallic enclosure
has a non-conductive coating. These may generate an ignition-
capable level of electrostatic charges under certain extreme
conditions. The user should ensure that the equipment is not
installed in a location where it may be subjected to external
conditions that might cause a build-up of electrostatic charges
on non-conducting surfaces.
6)
Product Mounting and Access
6.1 Mounting
The D2x Loudspeaker may be secured to any flat surface using
at least two of the three or four 7mm fixing holes. The enclosure
provides IP66 protection and is suitable for installation in exterior
locations providing it is positioned so that water cannot collect in
the horn, and the cable entry is sealed.
14
5
5
.7
1
in
.
30
1.
18
in
.
30
1.
18
in
.
236.9 9.33 in.
21
9.
6
8
.6
4
in
.
335.9 13.23 in.
314.5 12.38 in.
40
3.
2
1
5.
87
in
.
465.9 18.34 in.
55 2.17 in.
59
2.
32
in
.
59
2.
32
in
.
21
5
8
.4
6
in
.
Fig 1: Mounting Locations
The Equipment must not be installed with the horn facing upwards
of horizontal.
D2xL1F
D2xL2F
D2xL2H