7.4  Cable Glands, Blanking Elements & Adapters 
 
Ingress Protection 

 
If a high IP (Ingress Protection) rating is required then a suitable 
sealing washer must be fitted under the cable glands or blanking 
plugs.  A  minimum  ingress  protection  rating  of  IP6X  must  be 
maintained for installations in explosive dust atmospheres. 
 
To maintain the ingress protection rating and mode of protection, 
the  cable  entries  must  be  fitted  with  suitably  rated  cable  entry 
and/or blanking devices during installation. 
  

Adapters 

 
The D2x Loudspeaker range can be supplied with the following types 
of adapters: 
 

M20 to ½” NPT 
M20 to ¾” NPT 
M20 to M25 

 
It  is  important  to  note  that  stopping  plugs  cannot  be  fitted  onto 
adapters, only directly onto the M20 entries. 
 
To maintain the ingress protection rating and mode of 
protection, the cable entries must be fitted with suitably rated, 
certified cable entry and/or blanking devices during 
installation. 
 

8) 

Wiring 

 
The cable connections are made into the terminal blocks on the PCB 
assembly located in the enclosure. See section 6.4 of this manual for 
access to the enclosure. 
 
Refer to Wiring Schematic D190-06-201 Configs. 1a -2d or 4a-5f for 
Line in Loudspeakers and Config. 3 for Low impedance wiring details. 
 

9) 

End of Line Monitoring (DC Units) 

 
DC line monitoring can be used if required. Both the Line In units and 
the Low Impedance units have blocking capacitors fitted. It should be 
noted that each loudspeaker has a 1M ohm bleed resistor connected 
across  the  blocking  capacitor  and  this  should  be  taken  into  account 
when selecting the value of the end of line monitoring resistance. 
 
The  resistor must  be  connected  directly  across the  terminals.  Whilst 
keeping  its  leads  as  short  as  possible,  a  spacing  of  at  least  1/16” 
(1.58mm)  must  be  provided  through  air  and  over  surfaces  between 
uninsulated live parts. 
 
For Line in units the end of line resistor used must have minimum 
resistance values of: 
 
70/25V Line in Loudspeaker: 
Minimum resistance 3K9 Ohms  

Minimum Power 0.5W 

Minimum resistance 1K Ohms  

Minimum Power 2.0W 

 
100V Line in Loudspeaker: 
Minimum resistance 15K Ohms 

Minimum Power 0.5W 

Minimum resistance 3K9 Ohms 

Minimum Power 2.0W 

 
For Low Impedance units the end of line resistor used must have 
minimum resistance values of: 
 
Minimum resistance 2K Ohms  

Minimum Power 0.5W 

Minimum resistance 500 Ohms 

Minimum Power 2.0W 

 

On the low impedance units care must be taken with the polarity of the 
monitoring voltage. If an end of line resistor is fitted to a unit the links 
on the printed circuit boards of all loudspeakers in the line must be cut 
for the dc blocking capacitors to be in circuit in order to dc monitor the 
line (see Fig 5). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig. 5 Low Impedance Line Monitoring Link 

 

10) 

Maintenance, Overhaul and Repair

 

 
Maintenance,  repair  and  overhaul  of  the  equipment  should  only  be 
carried  out  by  suitably  qualified  personnel  in  accordance  with  the 
current relevant standards: 
 

For ATEX/IECEx or UKEx: 

 

EN60079-19/IEC60079-19  

 

Explosive  atmospheres 

–  Equipment  repair,  overhaul  and 

reclamation 

 

EN 60079-17/IEC60079-17    
Explosive  atmospheres 

– Electrical installations inspection 

and maintenance 

 
Units must not be opened while an explosive atmosphere is present. 
 
If opening the unit during maintenance operations, a clean 
environment must be maintained and any dust layer removed prior to 
opening the unit. 
 
Potential electrostatic charging hazard 

– Clean only with a damp 

cloth. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

DC Line 
Monitoring Link 

Summary of Contents for D2xL1 Series

Page 1: ...205 Ed 3 Signal Equipment UL 1480 Ed 6 Speakers for Fire Alarm and Signaling Systems Including Accessories CAN ULC S541 Ed 4 Speakers for Fire Alarm and Signaling Systems Including Accessories See rel...

Page 2: ...o 75 C Zone 22 AEx tc IIIC T119 C Dc Ta 55 C to 75 CEC Class Zone Ratings for Canada Standards CSA C22 2 No 60079 0 Ed 4 CSA C22 2 No 60079 7 Ed 2 CSA C22 2 No 60079 31 Ed 2 Model No Rating D2xL1 V100...

Page 3: ...e of the following standards EN60079 14 IEC60079 14 Explosive atmospheres Electrical installations design selection and erection EN60079 10 1 IEC60079 10 1 Explosive atmospheres Classification of area...

Page 4: ...st only be installed by suitably qualified personnel in accordance with the latest issues of the relevant standards The installation of the units must also be in accordance with the NEC CEC and any lo...

Page 5: ...into account when selecting the value of the end of line monitoring resistance The resistor must be connected directly across the terminals Whilst keeping its leads as short as possible a spacing of a...

Page 6: ...the 3 off 4 off 7mm holes in the mounting bracket The Equipment must not be installed with the horn facing upwards of horizontal If a high IP Ingress Protection rating is required then a suitable sea...

Page 7: ...D2xL2HR008 8 Ohm 25W 14 14V 105 18 D2xL2HR016 16 Ohm 25W 20 00V 104 92 CAN ULC S541 Directional Characteristics Unit Type ode Rated Angle Horizontal Axis Vertical Axis 3dB A 6dB A Reduction 90 3dB A...

Page 8: ...IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D252 06 201 D HOWGILL R N POTTS R N POTTS 18 11 20 OF NTS 1 5 1 INTRODUCTION RSR 12 10...

Page 9: ...OUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D252 06 201 D HOWGILL R N POTTS R N POTTS 18 11 20 OF NTS 2 5 18 11 20 18 11 20 D2xL1 D2xL2 L...

Page 10: ...L TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT...

Page 11: ...4 5 18 11 20 18 11 20 D2xL1 D2xL2 LINE IN LOW IMPEDANCE LOUDSPEAKER WIRING DIAGRAMS D2xL1 D2xL2 ve ve COM A B D2xL1V725 Line in Config 4a Optional Line Monitoring 15W 25V Apply Signal to Common A 70V...

Page 12: ...L1 D2xL2 D2xL2V725 Line in Config 5a Optional Line Monitoring 25W 25V Apply Signal to Common A 70V Apply Signal to Common C OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED MINIMUM VALUE R1 D2xL2V7...

Page 13: ...urance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812...

Page 14: ...the components contained within it are free from substances of very high concern Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure r...

Page 15: ...Assurance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 0518 Rake Lane Eccleston Chester CH4 9JN UK Quali...

Page 16: ...e components contained within it are free from substances of very high concern Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure rate...

Reviews: