INSTRUCTION MANUAL (ATEX / IECEx)
GNExS1
Alarm Horn Sounder
For use in Flammable Gas Atmospheres
European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D157-00-001-IS
Issue 7
02-11-21
Sheet 1 of 7
GNExS1R
GNExS1F
1) Product Table
Unit Type Code
Nominal
Input Voltage
Voltage Range
Nominal
Input Current
Max.
Current
Sound
Pressure Level
dB(A)
Max*
Nom
.†
GNExS1RDC024
12Vdc
10-30Vdc
221mA
221mA
110
105
24Vdc
185mA
GNExS1RDC048
48Vdc
38-60Vdc
115mA
221mA
110
105
GNExS1RAC230
115Vac
100-260Vac 50/60Hz
73mA
80mA
110
105
230Vac
48mA
GNExS1FDC024
12Vdc
10-30Vdc
221mA
221mA
115
110
24Vdc
185mA
GNExS1FDC048
48Vdc
38-60Vdc
115mA
221mA
115
110
GNExS1FAC230
115Vac
100-260Vac 50/60Hz
73mA
80mA
115
110
230Vac
48mA
*Max = Tone 4
†
Nom. = Tone 44
The table shows the input current taken by the various sounders.
A supply voltage variation of +/-10% outside the voltage range is permissible.
The current levels shown above are for the 440Hz Continuous tone @ nominal input voltage.
Nominal current at nominal voltage.
Max rated current at worst case supply voltage.
Table 1: Electrical Ratings.
Ensure the system power supply is capable of providing the maximum current required for all beacons. Review associated cable size,
length and quantity of beacons on each circuit.