8.2. Stage Switching Polarity (DC Units)
Switching from positive switching (default) to negative
switching - DC Only.
NOTE:
Max supply is 33V DC
–
if higher DC voltage is
required, use Negative switching.
Figure 8: Stage Switching Polarity.
8.3. Tone Selection
The ExS Alarm Horn Sounders have 64 different tones that
can be selected independently for the first and second stage
alarms. The tones are selected by operation of the tone setting
DIP switch 1 & DIP 2witch 2 (see figures 6 and 7) on the PCB,
for stage 1 and stage 2 respectively.
Default = S2
–
Tone 1
Default = S1
–
Tone 44
(ON = 1, OFF = 0)
Figure 9: DIP switch configuration
The sounder can also be switched to sound the third and fourth
stage alarm tones.
The tone table (D221-95-001-IS) shows the switch positions
for the 64 tones on first and second stages and which tones
are available for the third and fourth stages dependent on the
Stage 1 DIP switch setting.
Following table (Table 3) is a summary of wiring options.