Document No. IS 4601      Issue G                   13-01-20                       

Sheet 6 of 6

 

 

 
 
 
The IS-L101L Beacon has also been approved to the IECEx 
scheme.  
 
The installation requirements for IS-L101L beacons approved 
to  the  IECEx  scheme  are  the  same  as  the  installation 
requirements  for  IS-L101L  beacons  approved  to  the  ATEX 
directive. 
 
 
Certificate No. 

IECEx SIR 04.0039X 

 
 
Marking:  

Ex ia IIC T4 Ga (Ta = -40ºC to +60ºC) 

 
 
Standards: 

IEC 60079-0:2017 

 

 

IEC 60079-11:2011

 

 

CONDITIONS  OF  CERTIFICATION  (as  stated  on  the  IS-L101L 
Beacon IECEx Certificate of Conformity IECEx SIR 04.0039X) 

 

 

The equipment has an ingress protection rating of IP66; 
however,  if  it  has  been  supplied  without  a  cable  entry 
device, then the user shall ensure that the device that is 
fitted will provide an ingress protection that is appropriate 
to  the  environment  in  which  it  is  installed  i.e.  IP20  or 
better. If only one of the two cable entries are used, then 
the  unused  entry  shall  be  fitted  with  a  blanking  device 
that  ensures  ingress  protection  appropriate  to  the 
environment in which it is installed i.e. IP20 or better. 
 

 

The  enclosure  is  non-conducting  and  may  generate  an 
ignition-capable  level  of  electrosatic  charges  under 
certain extreme conditions. The user should ensure that 
the equipment is not installed in a location where it may 
be  subjected  to  external  conditions  that  might  cause  a 
build-up  of  electrostatic  charges  on  non-conducting 
surfaces,  additionally,  cleaning  of  the  equipment  should 
be done only with a damp cloth. 

 
 
The  IS-L101L  beacons  are  marked  with  the  certification 
requirements for the ATEX and IECEx approvals. 
 

e

2S

european safety systems ltd. 

London W3 7QH UK
www.e2s.com

WARNING: 

TO AVOID A POSSIBLE ELECTROSTATIC

 

CHARGE ONLY CLEAN WITH A DAMP CLOTH 

IS-L101L Beacon

II 1G

2813

SIRA 04ATEX2302X

Year / Serial No. 09 / 1000001

IECEx SIR 04.0039X

Ui = 28V  Ii = 660mA  Pi = 1.2W
Ci = 0  Li = 0

Ex ia IIC T4 Ga (-40ºC <=Ta<= +60°C)

 

 
 
 
 
 
 
 
 

If  the  IS-L101L  beacon  is  used  in  conjunction  with  an  IS-
A105N  sounder  then  the  following  certification  conditions 
apply:- 

 
CONDITIONS  OF  CERTIFICATION  (as  stated  on  the  IS-A105N 
Sounder IECEx Certificate of Conformity IECEx SIR 04.0038X) 
 

 

The  equipment  shall  only  be  supplied  via  Terminals  + 
w.r.t.  Terminals  -  from  a  certified  barrier  having  a 
maximum  open  circuit  voltage  Uo  that  is  less  than  or 
equal to 28 V and a maximum short circuit current Io that 
is  less  than  or  equal  to  93  mA,  where  Io  is  resistively 
limited. 

 

 

The total capacitance connected to ter wrt – (i.e. 
the capacitance of the cable plus any other capacitance) 
shall not exceed 83nF. 

 

 
 
 
 
 
 
 
The IS-L101L Beacon has also been FM Listed. 
 
 
Marking:           IS Class I, Zone 0, AEx ia IIC T4 
 
 

          IS Class I, Division 1, Groups A, B, C, D 

 
 
See  the  Control  Drawings  D  4627  Sheets  1  to  4  for 
installation details and entity parameters. 
 
 
The  IS-L101L  beacons  are  marked  with  the  certification 
requirements for the FM approval. 
 

WARNINGS:

IS-L101L Beacon

              To prevent ignition of flammable or combustible
              atmospheres, disconnect power before servicing

 

Substitution of components may impair safety 

FM

APPROVED

IS Class l, Division 1, Groups A, B, C, D
IS Class I, Zone 0, AEx ia IIC T4 (-40ºC <=Ta<= +60°C)

e

2S

european safety systems ltd.  London W3 7QH UK

Control Drawing D 4627

www.e2s.com

Year / Serial No. 09 / 1R000001

TO AVOID A POSSIBLE ELECTROSTATIC
 CHARGE ONLY CLEAN WITH A DAMP CLOTH 

 

 

 

 

IECEx Certification

FM Approval 

Summary of Contents for IS-L101L

Page 1: ...d reminder beep tone sound while the sounder is silenced The interval between the 1 second reminder beep is dependent on the timing setting for the silence period switches 1 to 4 see page 5 When the beacon is operated alone without a sounder connected all of the DIP switches should be set to the OFF position When used alone i e without a sounder connected two flash frequencies may be selected With...

Page 2: ...FE USE as stated on the IS L101L EC Type Examination Certificate SIRA 04ATEX2302X The enclosure is non conducting and may generate an ignition capable level of electrosatic charges under certain extreme conditions The user should ensure that the equipment is not installed in a location where it may be subjected to external conditions that might cause a build up of electrostatic charges on non cond...

Page 3: ...uitable for installation in an exterior location if an appropriate sealed cable entry is used 5 1 Mounting The IS L101L beacon may be secured to any flat surface using the two 6mm diameter fixing holes The lens should be aimed towards the area where maximum visibility is required 5 2 Installation procedure a Remove the beacon lens by unscrewing the two captive screws and pull the lens away from th...

Page 4: ...suitable for the environmental conditions to which it is subjected located within the same hazardous area as the beacon see section 4 5 In order that the beacon continues to produce a reasonable light output level when used in conjunction with an IS A105N sounder the power supply voltage to the barrier should be maintained at a minimum of 18V 7 ELECTRICAL SYSTEM DESIGN FOR INSTALLATION IN HAZARDOU...

Page 5: ...not been damaged Frequency of inspection depends upon environmental conditions but initially we recommend that this should be done annually No attempt should be made to repair a faulty IS L101L beacon Suspect beacons must be returned to European Safety Systems Ltd or to your local agent for repair 11 GUARANTEE Beacons which fail within the guarantee period should be returned to European Safety Sys...

Page 6: ...of the equipment should be done only with a damp cloth The IS L101L beacons are marked with the certification requirements for the ATEX and IECEx approvals e2S european safety systems ltd London W3 7QH UK www e2s com WARNING TO AVOID A POSSIBLE ELECTROSTATIC CHARGE ONLY CLEAN WITH A DAMP CLOTH IS L101L Beacon II 1G 2813 SIRA 04ATEX2302X Year Serial No 09 1000001 IECEx SIR 04 0039X Ui 28V Ii 660mA ...

Page 7: ...ngle channel barrier having parameters less than or equal to those quoted and for which the output is non ignition capable for the Class Division or Zone and Group of use 7 The IS L101L Beacon enclosure has an ingress protection rating of IP 66 If supplied without cable entry devices then metallic or plastic cable glands or conduit hubs shall be fitted that provide the required environmental prote...

Page 8: ...or equal to those quoted and for which the output is non ignition capable for the Class Division or Zone and Group of use 6 The IS L101L Beacon enclosure has an ingress protection rating of IP 66 If supplied without cable entry devices then metallic or plastic cable glands or conduit hubs shall be fitted that provide the required environmental protection 7 To prevent ignition of flammable or combu...

Page 9: ...onents may impair safety 10 C cable capacitance of cable connecting the shunt zener diode barrier to the beacon capacitance of the cable connecting the sounder to the beacon 11 The total capacitance connected to terminals of the beacon plus the total capacitance connected to terminals of the sounder i e C cable plus any other capacitance shall not exceed 83nF 12 L cable loop inductance of cable co...

Page 10: ...e sounder to the beacon 10 The total capacitance connected to terminals of the beacon plus the total capacitance connected to terminals of the sounder i e C cable plus any other capacitance shall not exceed 83nF 11 L cable loop inductance of cable connecting the galvanically isolated supply to the beacon loop inductance of cable connecting the sounder to the beacon Note CAUTION Bonding between con...

Reviews: