European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           sales@e2s.com              Tel: +44 (0)20 8743 8880 

                                                                                                                                                             www.e2s.com             Fax: +44 (0)20 8740 4200 
Document No. IS 5001      Issue H            03-01-2020                       

Sheet 2 of 6

 

3) 

The  equipment  is  only  certified  for  use  in  ambient 
temperatures  in  the  range  -40

o

C  to  +60

o

C  and 

should not be used outside this range. 

4) 

The  certificate  number  has  an  ‘X’  suffix,  which 
indicates  that  the  certificate  contains  one  of  more 
special  conditions  for  safe  use.  Those  installing  or 
inspecting the equipment should refer to this section 
of the certificate. 

5) 

The equipment has not been assessed as a safety-
related  device  (as  referred  to  by  Directive  94/9/EC 
Annex II, clause 1.5). 

6) 

Installation of this equipment shall be carried out by 
suitably-trained personnel in accordance with the 
applicable code of practice. 

7) 

Repair of this equipment shall only be carried out by 
the manufacturer or in accordance with the 
applicable code of practice. 

8) 

The certification of this equipment relies on the 
following materials used in its construction: 

 

 

 

Enclosure:

 

ABS Plastic

 

 

 

 

If the equipment is likely to come into contact with 
aggressive substances, then it is the responsibility of 
the user to take suitable precautions that prevent it 
from being adversely affected, thus ensuring that the 
type of protection is not compromised. 

 

“Aggressive substances” - e.g. acidic liquids or 
gases that may attack metals, or solvents that may 
affect polymeric materials. 

 

“Suitable precautions” - e.g. regular checks as part 
of routine inspections or establishing from the 
material’s data sheet that it is resistant to specific 
chemicals. 
 
 

SPECIAL  CONDITIONS  FOR  SAFE  USE  (as stated  in the 
EC Type Examination Certificate SIRA 05ATEX2084X)

 

Conditions for IS-mAl Sounder 

 
The  equipment  has  an  ingress  protection  rating  of  IP65. 
However, if it has been supplied without cable entry devices, 
then the user shall ensure that the devices that are fitted will 
provide  an  ingress  protection  that  is  appropriate  to  the 
environment in which it is installed i.e. IP20 or better. If only 
one of the two cable entries are used, then the unused entry 
'knockout'  shall  be  left  intact  or  fitted  with  a  blanking  device 
that  ensures  ingress  protection  appropriate  to  the 
environment in which it is installed i.e. IP20 or better. 
 
The total capacitance connected to ter wrt - (i.e. the 
capacitance of the cable plus any other capacitance) shall 
not exceed 83nF. 
 
The  enclosure  is  non-conducting  and  may  generate  an 
ignition-capable  level  of  electrostatic  charges  under  certain 
extreme  conditions.  The  user  should  ensure  that  the 
equipment  is  not  installed  in  a  location  where  it  may  be 
subjected  to  external  conditions  that  might  cause  a  build-up 
of  electrostatic  charges  on  non-conducting  surfaces, 
additionally,  cleaning  of  the  equipment  should  be  done  only 
with a damp cloth. 
 

The  equipment  shall  only  be  supplied  via  Terminals  +  w.r.t. 
Terminals  -  from  a  barrier  having  a  maximum  open  circuit 
voltage Uo that is < 28V and a maximum short circuit current 
Io that is < 93mA, where Io is resistively limited. The barrier 
shall be ATEX certified by a notified body. 
 

4.2  Zones, Gas Groups and Temperature Classification 

The  IS-mA1  minialarm  sounder  has  been  certified  Ex  ia  IIC 

T4.  When  connected  to  an  approved  system  it  may  be 

installed in: 

 

 

Zone 0 

explosive gas air mixture 

 

continuously present. 

 

Zone 1 

explosive  gas  air  mixture  likely  to  occur  in 

normal operation. 

 

Zone 2 

explosive  gas  air  mixture  not  likely  to  occur, 

and if it does, it will only exist for a short time. 

 

Be used with gases in groups: 

 

 

 

Group A 

propane 

 

Group B 

ethylene 

 

Group C 

hydrogen 

 

Having a temperature classification of: 

 

T1 

450ºC 

T2 

300ºC 

T3 

200ºC 

T4 

135ºC 

 

4.3  Ter and - 

Power  is  supplied  to  the  sounder  via  the  +  and  –  terminals 

which have the following input safety parameters: 

 

 

Ui 

28V 

 

Ii 

93mA 

 

Pi 

 

660mW 

 

 

Ci = 0  Li = 0 

 

The IS-mA1 sounder may be powered from an ATEX certified 

Zener  barrier  or  galvanic  isolator  which  have  output 

parameters  equal  to  or  less  than  28V,  93mA  and  660mW,

 

where  Io  is  resistively  limited.  The  cable  parameters  stated 

on  the  selected  Zener  barrier  or  galvanic  isolator  certificate 

must be observed. 

 

U

p  to  three  IS-mA1  sounders  can  be  connected  in  parallel 

and powered  from a  common  barrier or isolator.  Connecting 

two  sounders  in parallel will  reduce  the output from each by 

about  3dB.  Three  sounders  should  only  be  powered  from  a 

common  supply  when  the  maximum  supply  voltage  is 

available. 

 

4.4  Terminals S2 and S3  

When terminals S2 or S3 are connected to 0V (- terminal) the 

sounder  output  tone  changes  to  the  second  or  third  stage 

alarm  respectively.    The  input  safety  parameters  for  these 

terminals are: 

 

 

Ui 

28V 

 

 

Ii 

0mA  

 

Because  the  permitted  input current  is  zero,  these  terminals 

may  only  be  connected  to  a  diode  return  barrier,  an 

intrinsically safe relay or a galvanic isolator, all of which must 

have been certified by an EC Notified Body. Only diode return 

barriers  with  a voltage  drop  of  less  than 0.9V  may  be used. 

Alternatively, these terminals may be connected directly to a 

mechanically activated switch within the hazardous area. 

 

Summary of Contents for Minialarm IS-MA1-R

Page 1: ...e areas without a Zener Barrier or Galvanic Isolator but at supply voltages above 16V the internal current limit will function and therefore it is recommended that they are not operated continuously w...

Page 2: ...ny other capacitance shall not exceed 83nF The enclosure is non conducting and may generate an ignition capable level of electrostatic charges under certain extreme conditions The user should ensure t...

Page 3: ...400 2900Hz 50Hz Simulated bell Continuous 554Hz Continuous 440Hz Sweeping 800 1000Hz 7Hz Continuous 300Hz Sweeping 660 1200 1Hz Two Tone Chime Intermittent 745Hz Alternating 1000 2000Hz 0 5s Singapore...

Page 4: ...ble glands or conduit entries into the base and connect the field wiring to the appropriate sounder terminals as shown in section 6 and fig 2 of this manual The power supply terminals and are duplicat...

Page 5: ...ide of the isolator Safe Area Hazardous Area IS mA1 Sounder Galvanic Isolator Power Fig 7 Single stage alarm using galvanic isolator 7 2 Multi stage alarm The IS mA1 sounder second and third stages ma...

Page 6: ...additionally cleaning of the equipment should be done only with a damp cloth The equipment shall only be supplied via terminal w r t terminal from a barrier having a maximum open circuit voltage Uo th...

Page 7: ...h t d n a s n o i t a c o L h t r a e e h t d n a d n u o r g e f a s y l l a c i s n i r t n i e h t n e e w t e b e c n a t s i s e r e h T 5 m h o 1 e h t s s e l e b t s u m d n u o r g r e i r r...

Page 8: ...g n i t a r n o i t c e t o r p s s e r g n i n a s a h e r u s o l c n e r e d n u o S 1 A m S I e h T 6 c i t s a l p r o c i l l a t e m n e h t s e c i v e d y r t n e e l b a c t u o h t i w d e...

Reviews: