AVIIVA® EM2-EM4
21
1013D - AVIIVA EM2/EM4 02/11
e2v semiconductors SAS 2011
5.2
Serial Protocol and Command Format
The Camera Link interface provides two LVDS signal pairs for communication between the camera and
the frame grabber. This is an asynchronous serial communication based on RS-232 protocol.
The serial line configuration is:
Full duplex/without handshaking
9600 bauds (default), 8-bit data, no parity bit, 1 stop bit. The baud rate can be set up to 115200
5.2.1
Syntax
Internal camera configurations are activated by write or readout commands.
The command syntax for write operation is:
w <command_name> <command_parameters><CR>
The command syntax for readout operation is:
r <command_name><CR>
5.2.2
Command Processing
Each command received by the camera is processed:
The setting is implemented (if valid)
The camera returns “>”<return code><CR>
The camera return code has to be received before sending a new command.
Table 5-1. Camera Returned Code
Returned code
meaning
>0
(or “>OK”) : All right, the command will be implemented
>16
Command Error (Command not recognize or doesn't exist)
>33
Invalid Access (the receipt of the last command has failed).
>34
Parameter out of range (the parameter of the last command send is out of range).
>35
Access Failure (bad communication between two internal devices).
5.2.3
GenICam ready
The CameraLink Standard is not yet compliant with GenICam Standard, but as much as possible, each
command of the AVIIVA EM2/EM4 will have its correspondence with the Standard Feature Naming
Convention of the GenIcam Standard.
This correspondence is given in parenthesis for each feature/command as the following example :
•
Vendor name
(
DeviceVendorName
) : “
e2v
”