AVIIVA® EM2-EM4
23
1013D - AVIIVA EM2/EM4 02/11
e2v semiconductors SAS 2011
•
Device User ID
(
DeviceUserID
) : Camera user identifier ID
Read function : “
r cust
”;
Returned by the camera : String of 128 bytes (including “/0”)
Write function : “
w cust <idstr>
”
5.3.2
Dump and Communication
•
Dump
: Allows to dump all the Camera info/settings in a text file. This command is available in the
CommCam View Menu :
•
BaudRate
(
ComBaudRate
): Set the Camera BaudRate. This command is available in the CommCam “Com”
section :
Read function : “
r baud
”;
Returned by the camera : Value of the Baud Rate
Write function : “
w baud
” <index> with the index as follows :
1 : 9600 Bauds (default value at power up)
2 : 19200Bds
6 : 57600Bds
12 : 115200Bds
After changing the communication rate, the communication with the Camera could be interrupted
with the application (CommCam or whatever) it has made this change. The application has to
reconnect.with the appropriate baudrate. The baudrate will automatically switch to 9600 bds at
the next power down/up.