AVIIVA® EM2-EM4
27
1013D - AVIIVA EM2/EM4 02/11
e2v semiconductors SAS 2011
o
Medium 40MHz :
4 x channels diverging, interlaced by 2
5.3.5
Exposure and Synchronization
•
Synchronisation Mode
(
SynchroMode
) : Timed or Triggered, it defines how the grabbing is
synchronized
.
This command is available in the CommCam “Exposure” section :
Read function : “
r sync
”;
Returned by the camera :
•
0 : Free Run mode
•
1 : Ext Trig with Integration time set in the Camera
•
2 : Ext Trig with Integration time maximum in the line period
•
3 : Ext ITC (Integration Time Controlled) : The same Trig signal defines the line period and its
low level defines the integration time
•
4
:
Ext Trig with two trig signal : CC2 defines the start of the integration and CC1 defines the
Stop of the integration.
Write function : “
w sync
” <value>
Channel 1
Channel 2
Channel 3
Channel 4