D1 is a byte representing the invalid command code. It is defined as follows:
D1
bit 7
(parity)
bit 6
1
bit 5
1
bit 4
1
bit 3
0
bit 2
0
bit 1
command not executed
bit 0
command/data invalid
6.5
Application Notes
The following application notes apply to amplifiers with operating software SAMOS
issue 1 or higher.
Before attempting to control the amplifier using the RS-485 4-wire multi-drop bus,
check the following:
*
Ensure that the data connector is correctly wired (Rx+, Rx
7
are not reversed
etc.)
*
Check that the amplifier data rate is the same as that of the master (should be
set to 9600 baud).
*
Ensure that the amplifier has a unique address.
*
Check that the master has the same data format as the amplifier (1 start bit, 7
data bits, EVEN parity and 1 stop bit).
HBN63xx-1, Issue 8, Page 40