42
Region
Default Value
Vw
1
Vw
2
Australia A Voltage
253 V
260 V
Inverter maximum active power
output level (P)% of
S
rated
100%
20%
Australia B Voltage
250 V
260 V
Inverter maximum active power
output level (P)% of
S
rated
100%
20%
Australia C Voltage
253 V
260 V
Inverter maximum active power
output level (P)% of
S
rated
100%
20%
New
Zealand
Voltage
242 V
250 V
Inverter maximum active power
output level (P)% of
S
rated
100%
20%
Procedures to enable or disable the Volt-watt Response Mode:
Step1: go to ‘All Set Enable’ in the menu of ‘TECHNICAL SET’ and turn the
status to ‘ON’.
Step2: go to ‘Special Func’ and then go to ‘PU Curve’
Step3: enable or disable the ‘Volt-watt Response Mode’ by changing the
status to ‘ON’ or ‘OFF’.
NOTE
: This operation is for maintenance personnel only. Password
is required to access this part!