107
-
-
108
-
011
A8-03
The slave received data
0: Output frequency
1: Frequency reference
A8-11
Window width
0.20 to 10.00 Hz
F0-10
Max. Frequency
5.00 to 500.00 Hz
0
0.5 Hz
50.00 Hz
Keep the same setting of
this parameter for the master
and slave.
A8-02
Selection of action of the
slave in point-point com
-
munication
BIT2
:
whether to alarm
when it becomes off-line
F8-07
Acceleration time 4
0.0s to 6500.0s
0.0s
F8-08
Deceleration time 4
0.0s to 6500.0s
0.0s
F0-02
Command source selection
0: Operating panel
(keypad & display)
1: Terminal I/O control
2: Serial comms.
2
A0-00
Speed/Torque control
selection
0: Speed control
1: Torque control
1
A0-01
Torque reference source in
torque control
0: Set by A0-03
1: AI1
2: AI2
3: keyboard pointer
4: Pulse reference (
S
5)
5: Serial comms.
6: MIN (AI1, AI2)
7: MAX (AI1, AI2)
0
A0-03
Torque digital setting in
torque control
-
200.0% to 200.0%
130%
A0-07
Acceleration time in torque
control
0.00s to 65000s
0.00s
A0-08
Deceleration time in torque
control
0.00s to 65000s
0.00s
Function Code
Parameter Name
Setting
Setting Range
Note
● Do not set start frequency in torque control. Otherwise, larger rush-in current
results at start.
● Reduce setting of A8-11 of the slave in master and slave control but the setting
must be larger than 0.20 Hz. Meanwhile, if deceleration time is very short, in-
crease setting of A8-11 properly. The larger the setting of A8-11 is, the weaker
window effect will be obtained.
Set initial value to half of rated motor slip. You can obtain rated motor slip according to the
following formulas:
Number of pole pairs of motor (take an integer) = (60 x rated motor frequency)/rated motor speed
Synchronous motor speed = (60 x rated motor frequency)/number of pole pairs of motor
Rated motor slip = (synchronous motor speed - rated motor speed)/synchronous motor speed x
rated motor frequency
Flexible connection
For the master in speed control, perform the following settings. Note that only the setting of
F8-15 can be modified.
●
Function Code
Parameter Name
Setting
FD-00
Baud rate
Setting Range
Keep the same setting of
thousands position of this
parameter for the master
and slave.
0000 to 6039
A8-00
Point-point communication
0: Disabled
1: Enabled
A8-01
Master or slave selection
0: Master
1: Slave
F0-10
Max. Frequency
5.00 to 500.00 Hz
1
0
50.00 Hz
Keep the same setting of
this parameter for the
master and slave.
F8-15
Droop rate
0.00 to 10.00 Hz
1.00 Hz
F0-17
Acceleration time 1
0.0 to 6500.0s
Keep the same setting of
this parameter for the
master and slave.
EC590
Function parameters description
EC590