Digital setting of
torque limit in
speed control
(regenerative)
0.0% to 200.0%
150.0%
A2-50
0
A2-63
40
Motor 2 torque
boost
A5-01
0
PWM modulation
pattern
Random PWM depth
0
0: Disabled
1: Enabled
Overcurrent fast
prevention
1
100
to 110
Voltage over
modulation
coefficient
105
Excitation adjust
-
ment proportional
gain
A2-51
A2-53
Torque adjustment
proportional gain
0 to 20000
0 to 20000
Speed loop
integral separation
selection
A2-55
A2-59
Max. torque
coefficient of
field weakening
area
BIT0: Integral separation
0: Disabled
1
:
Enabled
A5
Control Optimization
Change
Function
Code
Setting Range
Default
Parameter Name
A5-04
A5-05
☆
☆
☆
☆
☆
☆
☆
☆
☆
0
0 to 20000
A2-52
Excitation adjust
-
ment integral gain
A2-54
Torque adjustment
integral gain
0 to 20000
50% to 200%
0: Disabled 1
:
Enabled
A2-60
Regenerative power
limit selection
0
☆
0: Same to Motor 1
1: Acceleration/Deceleration time 1
2: Acceleration/Deceleration time 2
3: Acceleration/Deceleration time 3
4: Acceleration/Deceleration time 4
A2-62
Motor 2 accelerat
-
ion/deceleration
time selection
0
☆
0: SVC
1: FVC
2: V/F control
A2-61
Motor 2 control
mode
0.0%: Automatic torque boost
0.1% to 30.0%
A2-65
Motor 2 oscillation
suppression gain
0 to 100
2000
1300
2000
1300
100%
Model
dependent
☆
★
☆
☆
A5-00
DPWM switchover
frequency upper
limit
5.00 Hz to the maximum frequency
0: Asynchronous modulation
1: Synchronous modulation
A5-02
Dead zone
compensation mode
selection
0: Disabled
1: Enabled (compensation mode 1)
A5-03
0: Random PWM invalid
1 to 10: Random PWM
1
8
.
00Hz
☆
☆
A5-06
A5-08
A5-09
Undervoltage
threshold
Dead-zone time
adjustment
Overvoltage
threshold
★
★
210
to
420V
100% to 200%
350V
A6-02
AI curve 4
inflection 1 input
A6-00
to A6-04
0
.
00V
100
.
0
%
☆
-
10
.
00V
☆
-
3
.
00V
☆
3
.
00V
30
.
0
%
☆
0.0%
-
10.00 V to A6-02
150%
Model
dependent
-
100
.
0
%
-
30
.
0
%
☆
☆
☆
☆
☆
☆
200.0V
to
2500.0V
☆
Change
Default
Function
Code
A 6
AI C ur ve S et tin g
Setting Range
Parameter Name
A6-06
AI curve 4 max.
Input
-
100.0% to +100.0%
A6-07
Corresponding
percentage of AI
curve 4 max. Input
A6-03
Corresponding
percentage of AI
curve 4 inflection
1 input
-
100.0% to +100.0%
A6-04
AI curve 4
inflection 2 input
A6-05
Corresponding
percentage of AI
curve 4 inflection
2 input
A6-02
to A6-06
-
100.0% to +100.0%
A6-00
AI curve 4 min.
Input
A6-01
Corresponding
percentage of AI
curve 4 min. Input
A6-10
AI curve 5
inflection 1 input
A6-14
AI curve 5 max.
Input
A6-15
Corresponding
percentage of AI
curve 5 max. Input
A6-11
Corresponding
percentage of AI
curve 5 inflection
1 input
A6-12
AI curve 5
inflection 2 input
A6-13
Corresponding
percentage of AI
curve 5 inflection
2 input
A6-08
AI curve 5 min.
Input
A6-09
Corresponding
percentage of AI
curve 5 min. Input
A6-24
Jump point of AI1
input corresponding
setting
0
.
0
%
3
.
00V
30
.
0
%
6
.
00V
60
.
0
%
10
.
00V
10
.
00V
100
.
0
%
☆
☆
☆
☆
☆
☆
☆
★
A6-04
to +10.00V
-
100.0% to +100.0%
-
10.00V to A6-10
-
100.0% to +100.0%
A6-08
to A6-12
-
100.0% to +100.0%
A6-10
to A6-14
-
100.0% to +100.0%
A6-12
to +10.00V
-
100.0% to +100.0%
-
100.0% to +100.0%
EC590
Function code table
EC590
Function code table
-
183
-
-