34
-
-
35
-
F u n c t i o n C o d e T a b l e
EC6000
F u n c t i o n C o d e T a b l e
EC6000
P9
-
05
2nd
fault type
Read-only
0905H
15 -- ERROR_EXTERNAL EQUIPMENT
16 -- ERROR_COMMUNICATE
17 -- ERROR_CONTACTOR
18 -- ERROR_CURRENT_DETECTION
19 -- ERROR_AUTO-TUNING
20 -- ERROR_ENCODER
21 -- ERROR_EEPROM_READWRITE
22 -- ERROR_HARDWARE_AC DRIVE
23 -- ERROR_MOTOR_SHORT_TO_GND
24 -- ERROR_ERRPROM_INITIALIZETE
26 -- ERROR_RUNNING TIME_REACHED
27 -- ERROR_USER-DEFINED_1
28 -- ERROR_USER-DEFINED_2
29 -- ERROR_POWER-ON_TIME_REACHED
30 -- ERROR_LOAD_0
31 -- ERROR_PID_FDB_LOSE
40 -- ERROR_PBP_CURRENT_LIMIT
41 -- ERROR_SWITCH_MOTOR_WHEN_RUN
42 -- ERROR_TOO_LARGE_SPEED_DEVIATION
43 -- ERROR_MOTOR_OS
45 -- ERROR_MOTOR_OH
51 -- ERROR_POLE_POSITION_DETECTION
52 -- ERROR_ZERO_POSITION_INDENTIFICATION
53 -- ERROR_FEEDBACK_UVW_SIGNAL
Read-only
3rd
fault type
P9
-
06
0906H
P9-07
P9-08
P9-09
P9-10
0907H
0908H
0.00~655.35Hz
BIT0:Direction of operation
0:FWD 1:REV
BIT1:Running state
0:STOP 1:CONST 2:ACC 3:DEC
BIT2:RESERVED
BIT3:RESERVED
0.1
~
2000.0A
Failure operation
frequency
Failure
output current
Failure
DC-bus voltage
Failure AC
drive status
Read-only
Read-only
Read-only
0909H
Read-only
090AH
P9
-
11
Failure S
terminal status
Read-only
090BH
See input terminal status diagram
P9
-
12
Failure Y
terminal status
090CH
See input terminal status diagram
P9
-
13
Failure
power on time
090DH
0
~
65535
P9
-
14
Failure
running time
090EH
0
~
65535
P9
-
15
Frequency
upon 2nd fault
090FH
0.00
~
655.35Hz
P9
-
16
Current upon
2nd fault
0910H
0.1
~
2000.0A
P9
-
17
Output voltage
upon 2nd fault
0911H
0
~
3000V
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
0
~
3000V
P9
-
18
AC drive status
upon 2nd fault
0912H
Same as P9-10
P9
-
19
S terminal status
upon 2nd fault
0913H
Same as P9-11
P9
-
20
Y terminal status
upon 2nd fault
0914H
Same as P9-12
P9
-
21
Power-on time
upon 2nd fault
Read-only
0915H
Same as
P9
-
13
P9
-
22
Running time
upon 2nd fault
Read-only
0916H
Same as
P9
-
14
P9
-
23
Frequency
upon 3rd fault
Read-only
0917H
0.00
~
655.35Hz
Read-only
Read-only
Read-only
P9-31
091FH
100
.
0
%
0
.
0
~
100
.
0
%
P9-32
0920H
1.00
0.20
~
10.00
P9-24
P9-25
P9-26
P9-27
P9-28
P9-29
P9-30
0918H
0919H
091AH
091BH
091CH
091DH
091EH
0.1
~
2000.0A
0
~
3000V
Same as
P9
-
10
Same as P9-11
Same as P9-12
Same as
P9
-
13
Same as
P9
-
14
Current upon
3rd fault
Output voltage
upon 3rd fault
AC drive status
upon 3rd fault
S terminal status
upon 3rd fault
Y terminal status
upon 3rd fault
Power-on time
upon 3rd fault
Running time
upon 3rd fault
Backup frequency
upon abnormality
Motor overload
protection gain
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
P9-33
0921H
90%
50~100%
Motor overload
warning coefficient
0~100%
P9
-
34
Recognize voltage
at instantaneous
stop action
80%
0922H
0~100%
P9
-
35
Recognize voltage
at instantaneous
stop action
80%
0923H
P9
-
36
Recognize time
at instantaneous
rise action
0.50s
0924H
0.00~100.00s
0~200%
P9
-
37
Instantaneous stop
deceleration gain
100%
0925H
0.0~100.0%
P9
-
38
Detection level of
load becoming 0
10.0%
0926H
0.0~60.0s
P9
-
39
Detection time of
load becoming 0
1.0s
0927H
0.0~50.0%(Maximum frequency)
P9
-
40
Over-speed
detection value
20.0%
0928H