FAULTS INDICATED BY THE ALARMS
SHEET A-1
ALARM(S)
PROBABLE CAUSE(S)
CORRECTIVE ACTION
Other alarm
description
The hardware version of the
3G PA-TRX module is not
recognised by the
synchronisation board
• Power up/down the IDR IDO 3G using the primary
converter's "I/O" switch (Plate 6.IV, item 2 or 9) (wait
until the power supply stops before putting the switch
back to "I").
• If the fault persists, replace the 3G PA-TRX module
(Sheet E-5).
• If the fault persists, contact the manufacturer's technical
support service.
FAULTS INDICATED BY THE ALARMS - 3G PA-TRX MODULE (3/3)