Maintenance
4-7
7
1
2
3
4
5
4.3.4
Support equipment
4.3.4.1
Measuring equipment and accessories
Note:
The user must ensure that the characteristics required of the measuring
equipment are correct at the time of measurement. Otherwise the equipment
should be calibrated (see measuring equipment manual).
DESIGNATION
SPECIFICATIONS
TYPE
SHEET
Multimeter fitted with the following
accessories:
Accuracy > 0.5 %
FLUKE FL79-III
• 1 red lead + 1 black lead each
fitted with a 4 mm banana plug.
• Supplied with the
FLUKE FL79-III
multimeter.
Power meter fitted with the
following accessories:
Accuracy > 1 %,
frequency range including
6.4 MHz
Agilent EPM 4418B
Series
• 1 power sensor
Range: 0 dBm to
+ 20 dBm, 50
Ω
Agilent E9304A 9 kHz to
6 GHz, - 60 dBm to
+ 20 dBm
• 1 coaxial adaptor female N / SMA
male
50
Ω
RADIALL R191327
Electronic counter fitted with the
following accessories:
Accuracy better than
0.01 ppm, frequency
range including 6.4 MHz
Agilent 53131A option
010 high stability (female
BNC output)
• 1 measurement cable male BNC-
female BNC
50
Ω
, length 1 m
Radiall type RG58
R141082/C291305/
R141237/100
• 1 coaxial adapter female BNC /
male SMA
50
Ω
Radiall R191303
Power reflection meter fitted with
the following accessories:
Frequency range
including 380 - 512 MHz
ROHDE & SCHWARZ
NAP ref. 0392.4017.04
• 1 cable for the power sensor
Supplied with the power
reflection meter
• 1 power sensor
Range: 10 mW to 30 W,
50
Ω
NRT-Z44 200 MHz to
4 GHz, 3 mW to 120 W
• adapters for connecting the
power sensors to the male N and
the male and female SMA
connectors
Table 4.4
LIST OF MEASURING EQUIPMENT AND ACCESSORIES