Installation, Operation and Parts Manual
EE-6501
22
5.4 Operation instructions
To avoid personal injury and/or property damage, permit only trained personnel to operate the lift.
After reviewing these instructions, get familiar with lift controls by running the lift t hrough a few cycles before loading vehicle on
lift. Always lift the vehicle using all four adapters. Never raise just one end, one corner or one side of vehicle.
The lift must be only used in a static position for lifting and lowering vehicles.
Turn SA1 to working mode and SA2
to “ON” mode before normal use.
The normal users are not allowed to open the door of control cabinet.
Raise the lift
Make sure vehicle is neither front nor rear heavy and center of balance should be midway between adapters and cent ered over
the lift.
1. Make sure that you have read and understood the operation manual before operation.
2.
Load vehicle on lift carefully. Position the lift adapters to contact at the vehicle manufacturer’s recommended lift points.
3. Push the UP button to
raise lift until adapters contact vehicle.
4
.
Check adapters for secure contact with vehicle. Raise lift to expected working height.
Lower the lift
When lowering the lift pay careful attention that all personnel and objects are kept clear.
1. Push the DOWNI button to lower the lifting platform. It will stop lowering at safety height.
2. Push DOWN II button to continue lowering the platforms which accompanies with safety alarming buzz.
3. After the lifting platform is fully lowered, remove rubber pads and other tools to provide an unobstructed exit for moving vehicle from
the lift area.
4. Drive the vehicle away.
Attention: In the case the desynchronisation of the two platforms are unacceptable (the difference is more than 6cm) during lifting
or lowering process, the synchronization protection device will be activated to stop any raising or lowering movement. In this cas e
the normal operator needs to ask professional help from maintenance operator to restore the lift to normal working condition.
HOW to restore to the normal working status?
Open the door of the control cabinet;
Turn SA2 to OFF mode;
PUSH DOWN I and DOWN II button to fully lower the platform;
Level until both platforms are synchronized. (Refer to Step 8: Levelling)
Turn SA2 to ON mode.
Summary of Contents for EE-6501
Page 10: ...Installation Operation and Parts Manual EE 6501 10 3 3 Dimensions...
Page 14: ...Installation Operation and Parts Manual EE 6501 14 Recessed mounting...
Page 27: ...Installation Operation and Parts Manual EE 6501 27 Annex 1 Wiring diagrams and parts list...
Page 28: ...Installation Operation and Parts Manual EE 6501 28...
Page 37: ...Installation Operation and Parts Manual EE 6501 37...