PCI 703 User Manual
Eagle Technology - Data Acquisition
Eagle Technology © Copyright 2001-2004 – www.eagledaq.com
2
Feature
PCI 703S-8
PCI 703S-8A
PCI 703S-16
PCI 703S-16A
Number of analog input channels
8
16
16
16
Number of analog output channels
0
2
0
2
A/D resolution @ 400 KHz
14
14
14
A/D FIFO depth
4096
4096
4096
4096
A/D channel list depth
4096
4096
4096
4096
D/A resolution @ 100 KHz
-
14
-
14
D/A FIFO depth
-
4096
-
4096
D/A waveform generation capability
-
YES
-
YES
Triggering capability
Internal, External.
Analog & Digital.
Post & Pre-Trigger
Internal, External.
Analog & Digital.
Post & Pre-Trigger
Internal, External.
Analog & Digital.
Post & Pre-Trigger
Internal, External.
Analog & Digital.
Post & Pre-Trigger
Counters
3
3
3
3
Frequency generation
1
2
1
1
Number of digital input/output lines
8
8
8
8
Number of multi function digital I/O lines
10
10
10
10
Table 1-2 PCI703S Versions
Applications
The PCI703 can be used in the following applications:
•
Vibration monitoring.
•
Transducer monitoring.
•
Automation and test equipment.
•
Signal generation.
•
Laboratory training.
•
Medical applications.
Key Specifications
•
14-bit analog input @ 400 KHz.
•
Fully programmable sample-and-hold analog input system with triggering.
•
14-bit analog output @ 400 KHz.
•
Independent waveform generation capability.
Software Support
The PCI703 is supported by EDR Enhanced and comes with an extensive range of examples.
The software will help you to get your hardware going very quickly. It also makes it easy to
develop complicated control applications quickly. All operating system drivers, utility and test
software are supplied on the Eagle Technology CD-Rom. The latest drivers can also be
downloaded from the Eagle Technology website. For further support information see the
Contact Details section.
Contact Details
Below are the contact details of Eagle Technology.
Eagle Technology
PO Box 4376
Cape Town
8000
South Africa
Tel27 (021) 423 4943
Fax +27 (021) 424 4637
E-Mail
eagle@eagle.co.za