11
AVI Slide Rev - C
Control Board
FEATURE SELECTOR
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
234
OFF—ON
SELECT
MOTOR 15A
OPENING
TIMER
ERD CONTROL
MULTI FUNCTION
GATE STATUS
FEATURE SELECTOR
M/S PHASE
1
0
CLOSING
MASTER
OPEN RIGHT
BRAKE ON
CLOSE TIMER ON
SLAVE
OPEN LEFT
BRAKE OFF
CLOSE TIMER OFF
1
ON
2
3
4
OFF—ON
SELECT
MIN
MAX
OPEN
LIMIT
ERD OVERLOAD
OPENING CLOSING CLOSED
LIMIT
SLAVE MASTER
+ –
+ –
#9
#8
+ MAGLOCK
- 24 VDC
#5
+ ALARM
- 12 VDC
#6
REVERSE
LOOP
#2
POWER
24V
AC
#7
KEY
#3
M-FCN
#4
GND
GND
RCVR
24VAC
#1
COMM PORT
INPUT/OUTPUT
RECEIVER
ERD
M/P
RESET
1
O
N
2
ON ON STOP N/C
ON OFF CLOSE
OFF ON PHANTOM
OFF OFF EDGE SENSOR
S1 S2 FCN
COMM PORT
POWER
CONTROL BOARD ADJUSTMENTS AND WIRING
Feature Selector Switches #1 - #4
Control Board Overview
The Feature Selector Descriptions:
NOTE:
The power MUST be turned OFF before changing the features selector switches.
Switch #1:
Slave/Master - Sets the operator to work as Master or Slave. Single operator
installation
MUST
be set to
MASTER
.
Switch #2:
Gate Opening - designates left or right opening direction. See page 12.
Switch #3:
Motor Brake - If the ON position is selected, the gate will stop instantly when
the limit switch is activated. This is useful for uphill/downhill applications and on all
fail-safe operators.
Switch #4:
Close Timer (ON/OFF) - Turns the close timer ON or OFF. See page 14.
M/S Phase
DO NOT
remove jumper or operator will
NOT
function.
Designates communication between master and slave
operators only. M/S operators can be set for the same
or opposite phase, depending on operators
communication (can vary). See page 17.
Reset Button
Press for soft reset of operator (resets board microprocessor,
applies any changes that have been made to switches).
Turns OFF activated alarm. Try this button before preforming
a hard shutdown of operator (turn power switch OFF/ON)
when operator fails.
Multi Function
See page 15
Input/Output Connections
Descriptions - See page 15
Wiring Accessories - See page 16
Fuse
15 Amp
250V
Slow-Blow
Factory Set
ERD Sensor
“Fine Tune”
Adjustment.
Please call
Eagle
Access
before any
adjustment.
See page 14
Master/Slave
See page 17
Radio Receiver
See page 13
See page 14
Not Used
Not Used
Feature Selector
Close Timer
-
See page 14
Reverse ERD
Sensor
See page 14
Limit Switches
See page 12
Summary of Contents for AVI
Page 2: ...2 AVI Slide Rev C ...
Page 23: ...21 AVI Slide Rev C NOTES ...