6
AVI Slide Rev - C
General Safety Information Continued
Closing Gate
Incorrect
Correct
Obstructing
Wall
Catch Rollers
(Safety Cover)
Catch Post
Minimum of
3" Clearance
between gate and
obstructing wall or other object in
OPEN
Position.
3"
4"
DO NOT
install a stop or catch post in front of the gates path. To do so will cause the gate to hit the post in certain instances. Install catch rollers on the side of
a post or wall. When gate is fully
OPEN
, the end of the gate MUST stop at least three inches from a obstructing wall or object. The
CLOSED
gate should overlap
at least four inches from the wall or fence. Positive stops MUST be installed. Install screen or mesh on gate if necessary (see below).
Gate in Fully
OPEN
Position
Gate in
Fully
CLOSED
Position
Minimum of
4" gate overlap
from
wall or fence in
CLOSED
Position.
Wall or Fence
Closing Gate
POSITIVE STOPS
MUST be installed on
EACH
end
of the gate so the gate does
NOT
exceed the limit
of the rail and derail while
OPENING
or
CLOSING
.
Gate in
Fully
CLOSED
Position
6 ft min above ground
Ornamental Grill Styled Gates:
Injuries may be avoided if a mesh screen is
installed on the gate. Injuries resulting from hands and feet becoming stuck in
the gate or children riding on the gate while gate is moving can be greatly
reduced if this “screen” or “mesh” is applied to the gate as a safety precaution.
Guide Rollers
Gate Stopping Positions
Positive Stops
Screen or Mesh
Gener
al Safety
Summary of Contents for AVI
Page 2: ...2 AVI Slide Rev C ...
Page 23: ...21 AVI Slide Rev C NOTES ...