background image

INSTALLATION OPERATING & MAINTENANCE INSTRUCTIONS

Gas Fryer (NG Unit)

5

(continued on next page)

/ .

-

9

<

;

=

0

<

;

=

E

E

!

%

%

/ .

-

9

<

;

=

0

<

;

=

E

E

!

%

%

Step 3.

Turn  the  Gas  Control  Valve  dial  to  “Pilot”  position  and  press  and  hold.  Press  the  pilot
ignition button. If the unit does not light, continue pressing and holding the pilot button
and press the ignition button again. Purging air from the system may take 5–7 minutes on
first use. 

Step 2.

Ensure the thermostat dial is at the “OFF” position.

Operating Instruction:

Step 1.

Ensure this Gas Control Valve dial is at the “OFF” position. 

LIGHTIING INSTRUCTIONS

Fryers are furnished with a Gas Control Safety Valve. Please follow the instructions below.

Before Lighting Pilot and Burners

Fill the fat tank about 3/4" below the full line with proper frying compound before lighting pilot. The
reason for filling the tank 3/4" below the full line is that the frying compound will expand during the
preheating process.
If the frying compound expands above the full line, the frying compound may overflow out of the tank
during the cooking process. The reason for adding fry compound in fry tank before lighting the pilot
or burners is that the unit will be damaged if this is not done.

Summary of Contents for CLGF30-NG

Page 1: ... AVERTISSEMENT L installation le réglage la modification la réparation ou l entretien incorrects de cet appareil peuvent causer des dommages matériels des blessures ou la mort Lire attentivement les instructions d installation de fonctionnement et d entretien avant de procéder à son installation ou entretien WARNING Instructions must be posted in a prominent location All safety precautions must be...

Page 2: ... d arrêt manuel pendant tout test de pression du système de canalisation de gaz à pression de test égale ou inférieure à psi 3 45 kPa TABLE OF CONTENTS ITEM PAGE Safety precautions 3 General Installation Instructions 4 Specifications Dimensions 4 Lighting Instructions 5 Operating Instructions 6 Cleaning Maintenance 7 8 Troubleshooting 9 Exploded View 10 Replacement Parts List 11 Warranty 11 Congra...

Page 3: ... which could result in serious injury or death AVERTISSEMENT Ce symbole désigne un possible danger ou une pratique dangereuse qui pourrait entraîner des blessures graves ou la mort CAUTION This symbol refers to a potential hazard or unsafe practice which could result in minor or moderate injury or product or property damage ATTENTION Ce symbole désigne un possible risque ou une pratique dangereuse...

Page 4: ...ANCE Combustible clearances 6 sides 152mm 6 rear 152mm 4 floor 102mm Non combustible clearances 0 sides 0mm 0 rear 0mm 4 floor 102mm Do not obstruct the flow of combustion and ventilation air under the unit by the legs or behind the unit by the flue Ne pas obstruer le flux d entrée et de sortie d air de combustion et de ventilation sous l unité par les pattes ou derrière l appareil par le conduit ...

Page 5: ...is Gas Control Valve dial is at the OFF position LIGHTIING INSTRUCTIONS Fryers are furnished with a Gas Control Safety Valve Please follow the instructions below Before Lighting Pilot and Burners Fill the fat tank about 3 4 below the full line with proper frying compound before lighting pilot The reason for filling the tank 3 4 below the full line is that the frying compound will expand during the...

Page 6: ...he unit s sides or back Avoid wall type fans which create air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a subnormal atmospheric pressure will occur which will effect operation and cause undesirable working conditions A properly designed and installed hood ...

Page 7: ...ce a week 4 Strain the frying compound into a clean container Make sure there is no compound left in tank If the tank is left empty for more than 2 minutes shut the pilot off If this is not done the tank may be damaged 5 Add water to the MAX line 6 Add any good grade of cleaner following cleaner instructions 7 Turn the thermostat to 75 F dial F position Let the heating unit bring the solution to a...

Page 8: ...quefy Add to adjust compound level 3 Use a quality frying compound 4 Filter the frying compound frequently at least once a day 5 Skim out food particles frequently with a strainer skimmer 6 Add at least 15 of fry tank capacity of fresh frying compound daily more if possible without overloading tank If 15 of frying compound is not used daily remove some of the compound for other use gravy griddle f...

Page 9: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS Gas Fryer NG Unit 9 continued on next page 0 0 D 0 0 0 1 0 D 0 94 94 94 94 3 D D 1 1 TROUBLESHOOTING GUIDE ...

Page 10: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS Gas Fryer NG Unit continued on next page 10 optional MODEL CLGF30 NG EXPLODED VIEW ...

Page 11: ...ts and service centers near you contact the factory for assistance This warranty does not cover any cost associated with maintenance misuse abuse improper installation pilot light adjustments pilot outage improper ventilation adjustments alteration calibration wrong voltage wrong gas voltage or gas conversions resetting of circuit breakers or safety controls overtime charges travel charges on port...

Page 12: ...rvice equipment eagle Mhc specFAB and retail Display are divisions of eagle Group 2016 by the eagle Group 100 Industrial Boulevard Clayton Delaware 19938 8903 U S A www eaglegrp com Phone 302 653 3000 Foodservice 800 441 8440 MHC Retail 800 637 5100 Fax 302 653 2065 End Figure 1 ...