DCS-302 Load Cell Replacement
Remove four screws holding the lid.
Disconnect the load cell that needs to be replaced from the terminal block. Loosen the strain relief on
the bottom of the divider plate and pull the wire through.
Load cells and adjustment bolt pictured below for reference. Note how high the bolt is above the nut
on
your scale
. When installing the new cell, adjust it so it’s about the same height.