COMPLETE BATTERY DISCHARGE
To protect battery life, the Eagle-DC Gate Operator automatically shuts down when
battery voltage drains to the minimum allowable for safe operation.
If shut down occurs due to lost battery voltage, select the Power Fail Operation to
HOLD OPEN or HOLD CLOSED until AC power or battery voltage is restored.
HOLD OPEN During Complete Battery Discharge
S
TEP
1
. Find DIP Switch Panel Labeled “PWR FAIL OPERATION”
S
TEP
2
. Turn Switch 1 to the OFF position for Battery Back-up Operation (page 15)
S
TEP
3
. Turn Switch 2 to the OFF position
R
ESULT
. During Battery Back-up Operation, if battery voltage drains to its minimum
allowable level, the gate will move to the full open position and remain open until AC
power restored or battery voltage returns to normal.
HOLD CLOSED During Complete Battery Discharge
S
TEP
1
. Find DIP Switch Panel Labeled “PWR FAIL OPERATION”
S
TEP
2
. Turn Switch 1 to the OFF position for Battery Back-up Operation (page 15)
S
TEP
3
. Turn Switch 2 to the ON position
R
ESULT
. During Battery Back-up Operation, if battery voltage drains to its minimum
allowable level, the gate will move to full closed position and remain closed until AC
power is restored or battery voltage returns to normal.
PWR FAIL OPERATION
Complete Battery Discharge:
HOLD OPEN
Switch 2 POWER FAIL OPEN
OFF
PWR FAIL OPERATION
Complete Battery Discharge:
HOLD CLOSED
Switch 2 POWER FAIL CLOSE
ON