Eagle Access Control Systems, Inc. www.EagleOperators.com
8
MEASUREMENTS FOR MOUNTING (C
ONTINUED
)
INSTALLATION
Optional Method: Push Gate Open
Note: The following are example applications. Your application may vary.
It is the installer’s responsibility to choose the most suitable dimensions based on site-
specific issues.
Measure the length of measurement A and B (See Dimensions This Page). Connect the Rear
Bracket and Supplemental Bracket to proper dimensions. Mount to column.
Open the gate to the full open position (Maximum 90°) and measure E.
Connect to the front bracket.
Inside
Attach Rear
Bracket to the
Supplemental
Bracket,
Opening
A
B
E
90°
7-3/4”
7-3/4”
36-7/32”
Opening
A
B
E
90°
5”
5”
28-11/32”
E
AGLE
-E7 — G
ATE
L
EAF
TO
16’
E
AGLE
-E7
SHORT
— G
ATE
L
EAF
TO
10’
Outside