____________________
Description of Inputs
Close
-
Momentary or Continuous Signal
Once activated the gate will fully close. Activation while
the gate is opening has no effect.
Timer Off - Momentary Input
This function must be released and reentered to be
recognized. This input is to be used for COMMAND OPEN
/ COMMAND CLOSE applications. The first signal will cause
the gate to begin opening. The second signal will close the
gate only when the gate is in the fully open position.
Reverse Loop
-
Momentary or Continuous Signal
This input is active only when the gate is closing or when
its fully open. If this input is active, the close timer is dis-
abled. All vehicle detectors and photo-eyes should be
connected here. Multiple devices may be connected in
parallel.
Stop
-
Momentary or Continuous Signal
This function overrides all other signals. Once activated,
the gate will immediately stop and await a new command.
If the stop input is continuously activated, the gate will not
move.
Key / Keypad
Timer On
-
Momentary or Continuous Input
Once activated the gate will fully open. Activation while the
gate is closing will cause the gate to reopen. Continuous
activation while the gate is open will disable the timer to
close function from automatically closing the gate.
Edge Sensor
-
Momentary or Continuous Signal
This signal is active when the gate is opening and/or
closing.
Multiple devices may be connected in parallel to the
Edge Sensor Input.
Phantom Loop
-
Momentary or Continuous Signal
This input is active only when the gate is at rest in the
fully open position. The input has no effect on the gate
when fully closed or while closing or opening. Continuous
activation will prevent the gate from moving in the close
direction. When the input is removed normal operation is
resumed. This input is intended for a vehicle loop detector
to sense a vehicle in the gate path. Multiple devices may
be connected in parallel.
If activated when the gate is opening:
The gate will stop, pause and reverse in the close
direction for 1 1/2 seconds and stop. Continuous
activation will prevent the gate from moving in the
opening direction. If the second activation occurs before
the limit switch is activated, the gate will stop and reverse
direction for 1 1/2 seconds and stop, thus activating the
alarm mode. At this point the operator must be manually
reset (ON/OFF) before normal operation can resume.
If activated when the gate is closing:
The gate will stop, pause and fully reopen. During this
mode the timer to close, reverse loop, exit loop and
phantom loop are disabled. The Key / Keypad and
Receiver will cause the gate to close if a second
activation occurs before the limit switch is activated. The
gate will then stop and reverse direction for 1 1/2 seconds,
stop again, thus activating the alarm mode. At this point
the operator must be manually reset (ON/OFF) before
normal operation can resume.
REVERSE LOOP INPUT
KEY / KEYPAD INPUT
MULTI-FUNCTION INPUT
(16)
Eagle Access Control Systems, Inc. / (800) 708-8848 / www.eagleoperators.com
EAGLE-II Swing Gate Operator
Summary of Contents for Power II
Page 1: ...I NSTALLATION M ANUAL ...